A wide area fault detection algorithm for transmission networks equipped with series compensation units

International Journal of Applied Power Engineering (IJAPE) · Vol. 8 No. 1 (2019) · hlm. 49–60

DOI
10.11591/ijape.v8.i1.pp49-60
ISSN
2722-2624, 2252-8792
Terbit
2019-04-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In this paper, a wide area back-up protection (WABP) algorithm is presented based on phasor measurement units (PMUs) measurements placed across the transmission network. The proposed algorithm computes a selected index named as positive sequence power index (PSPI) to detect faults in the network. Firstly, the network is subdivided into back-up protection zones. For each zone, the PSPI index is computed as absolute the value of the difference between the positive sequence sent and received phasor powers across the terminals of the zone. For each zone, the PSPI is compared to a predefined threshold to detect faults. One of the contributions in this paper is the usage of mathematical formulation to set the threshold values for each zone rather than experimental trials usually used in previous literature. In addition, the algorithm doesn’t depend iterative solutions nor line parameters of the network as usually used in WABP schemes. These advantages enhance the degree of confidence in decisions of the algorithm and reduces computational burdens to trivial amount. The presented algorithm (Level-1) could be enhanced into (level-2) if PMUs are available on all buses and in such case, the faulty line could be detected directly in a single step. WSCC 9-bus system and NE 39-bus systems were considered to accomplish this study. Severe cases for series compensated lines were taken into consideration including voltage or current inversion. Simulation results emphasis on algorithm’s robustness and adaptability.

Jaringan kolaborasi para penulis

10 penulis · 18 tautan kepenulisan bersama · 12 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Benha University
  • Egyptian Russian University
  • Al-Azhar University
  • Kafrelsheikh University
  • Jazan University
  • Helwan University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mahmoud Nour AliBenha University2
Mahmoud A. El‐DabahAl-Azhar University1
Ragab Abdelaziz El-SehiemyKafrelsheikh University1
Zuhair Muhammed AlaasJazan University1
Mohamed M. RamadanHelwan University1
Abdelrahman SaidBenha University1
A. SaidBenha University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A wide area fault detection algorithm for transmission networks equipped with series compensation units</dc:title>
	<dc:creator>Ebrahim, Mohamed A.</dc:creator>
	<dc:creator>Wadie, Fady</dc:creator>
	<dc:creator>Abd-Allah, Mousa A.</dc:creator>
	<dc:description xml:lang="en-US">In this paper, a wide area back-up protection (WABP) algorithm is presented based on phasor measurement units (PMUs) measurements placed across the transmission network. The proposed algorithm computes a selected index named as positive sequence power index (PSPI) to detect faults in the network. Firstly, the network is subdivided into back-up protection zones. For each zone, the PSPI index is computed as absolute the value of the difference between the positive sequence sent and received phasor powers across the terminals of the zone. For each zone, the PSPI is compared to a predefined threshold to detect faults. One of the contributions in this paper is the usage of mathematical formulation to set the threshold values for each zone rather than experimental trials usually used in previous literature. In addition, the algorithm doesn’t depend iterative solutions nor line parameters of the network as usually used in WABP schemes. These advantages enhance the degree of confidence in decisions of the algorithm and reduces computational burdens to trivial amount. The presented algorithm (Level-1) could be enhanced into (level-2) if PMUs are available on all buses and in such case, the faulty line could be detected directly in a single step. WSCC 9-bus system and NE 39-bus systems were considered to accomplish this study. Severe cases for series compensated lines were taken into consideration including voltage or current inversion. Simulation results emphasis on algorithm’s robustness and adaptability.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2019-04-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/15600</dc:identifier>
	<dc:identifier>10.11591/ijape.v8.i1.pp49-60</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 8, No 1: April 2019; 49-60</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v8.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/15600/12415</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>