Akses terbuka
Jurnal
SINTA 1
Realtime hybrid offline-online power loss analysis-based Simulink simulation
International Journal of Applied Power Engineering (IJAPE) · Vol. 12 No. 1 (2023) · hlm. 49–61
ISSN 2722-2624, 2252-8792
Terbit 2023-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
The power distribution system applied in Indonesia is the radial system. The system is considered to be the simplest and most economical. The bad or good distribution of electrical power can be observed from the quality of the distribution of power supplied. Voltage has to be monitored and kept constant. An analysis was conducted at Bendul Merisi Feeder which has 11 buses, to find the value of supplied power also the value of voltage drop of each bus. The Simulink method is used to simulate and analyze active and reactive power at each cluster. Based on the result of the simulation analysis, the average was obtained by adding up electrical power received every hour, then dividing by 10, the number of buses connected to the load. The smallest average of active power supplied to each bus happened at 09.00 a.m., i.e. 112137.94 VA. The biggest value of active power supplied to each bus happened at 1.00 p.m., i.e. 115129.05 VA. The total voltage drop that occurred in the distribution supply was 224 volts or 1.12% out of 20 kV supplied, indicating that the supply of voltage was according to the standardized rule implemented by PLN (State Electricity Company), i.e. the voltage drop should not exceed the maximum of 10%.
Jaringan kolaborasi para penulis
4 penulis ·
4 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Institut Teknologi Adhi Tama Surabaya Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Realtime hybrid offline-online power loss analysis-based Simulink simulation</dc:title>
<dc:creator>Sulistyowati, Riny</dc:creator>
<dc:creator>Prawidya, Ganesha Fikri</dc:creator>
<dc:creator>Sujono, Hari Agus</dc:creator>
<dc:subject xml:lang="en-US">arduino; distribution; electrical energy; electrical power; MATLAB; Simulink</dc:subject>
<dc:description xml:lang="en-US">The power distribution system applied in Indonesia is the radial system. The system is considered to be the simplest and most economical. The bad or good distribution of electrical power can be observed from the quality of the distribution of power supplied. Voltage has to be monitored and kept constant. An analysis was conducted at Bendul Merisi Feeder which has 11 buses, to find the value of supplied power also the value of voltage drop of each bus. The Simulink method is used to simulate and analyze active and reactive power at each cluster. Based on the result of the simulation analysis, the average was obtained by adding up electrical power received every hour, then dividing by 10, the number of buses connected to the load. The smallest average of active power supplied to each bus happened at 09.00 a.m., i.e. 112137.94 VA. The biggest value of active power supplied to each bus happened at 1.00 p.m., i.e. 115129.05 VA. The total voltage drop that occurred in the distribution supply was 224 volts or 1.12% out of 20 kV supplied, indicating that the supply of voltage was according to the standardized rule implemented by PLN (State Electricity Company), i.e. the voltage drop should not exceed the maximum of 10%.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US">South Surabaya PLN</dc:contributor>
<dc:date>2023-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20508</dc:identifier>
<dc:identifier>10.11591/ijape.v12.i1.pp49-61</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 12, No 1: March 2023; 49-61</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v12.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20508/13047</dc:relation>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/downloadSuppFile/20508/2822</dc:relation>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/downloadSuppFile/20508/2823</dc:relation>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/downloadSuppFile/20508/2824</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Riny Sulistyowati</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Sulistyowati, R., Prawidya, G. F., & Sujono, H. A. (2023). Realtime hybrid offline-online power loss analysis-based Simulink simulation. International Journal of Applied Power Engineering (IJAPE), 12(1), 49–61. https://doi.org/10.11591/ijape.v12.i1.pp49-61
Salin
IEEE
R. Sulistyowati, G. F. Prawidya, and H. A. Sujono, “Realtime hybrid offline-online power loss analysis-based Simulink simulation,” International Journal of Applied Power Engineering (IJAPE), vol. 12, no. 1, pp. 49–61, 2023, doi: 10.11591/ijape.v12.i1.pp49-61.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.