Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Novel approach for assessing the maximum load capacity of buses within a power transmission network

International Journal of Applied Power Engineering (IJAPE) · Vol. 15 No. 3 (2026) · hlm. 1105–1116

DOI
10.11591/ijape.v15.i3.pp1105-1116
ISSN
2722-2624, 2252-8792
Terbit
2026-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Achieving a balance between the satisfaction of energy requirements and adherence to environmental and social regulations stipulated in international agreements necessitates the rigorous management of existing electricity systems by electricity network operators, thereby ensuring that thermal and stability limits are not exceeded. Consequently, the assessment of load bus maximum capacity (LBMC) at any given load bus (LB) becomes imperative for ensuring the reliability and efficiency of electricity transmission networks. The extant literature on the subject of assessing LBMC in electrical networks either fails to take into account the combined effects on such networks of their various load points or, if it does, it is computationally intensive. The approach proposed in this paper involves a simplified method for assessing the LBMC for each of the LBs in the network. This is achieved to ensure that the combined effect of increasing the load on each of these buses does not compromise the load planning determined by a given network performance index, either during normal operation or in the event of a malfunction. The findings substantiate the efficacy of the proposed methodology, which facilitates the reliable estimation of LBMC. The reliability of this approach is ensured by the selection of a reliable performance indicator, which in our case is the complex stability index for transmission lines (CSITL).

Kata kunci

Jaringan kolaborasi para penulis

11 penulis · 35 tautan kepenulisan bersama · 24 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Université d'Abomey-Calavi
  • National University of Sciences, Technologies, Engineering and Mathematics
  • Université Nationale d'Agriculture
  • Université de Maradi
  • University of Douala
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Abdoul Malik Maman IssakaAfiliasi tidak diketahui4
D’Almeida Renaud PhilippeUniversité d'Abomey-Calavi1
Macaire Bienvenu AgbomahenaUniversité d'Abomey-Calavi1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Novel approach for assessing the maximum load capacity of buses within a power transmission network</dc:title>
	<dc:creator>Gonda, Moussa</dc:creator>
	<dc:creator>Oloulade, Arouna</dc:creator>
	<dc:creator>Agbokpanzo, Richard Gilles</dc:creator>
	<dc:creator>Aza-Gnandji, Maurel Richy</dc:creator>
	<dc:creator>Ibrahim, Hassane Ousseyni</dc:creator>
	<dc:creator>Nounangnonhou, Cossi Télesphore</dc:creator>
	<dc:creator>Fifatin, François-Xavier</dc:creator>
	<dc:creator>Imano, Adolphe Moukengue</dc:creator>
	<dc:subject xml:lang="en-US">CSITL; global effect load factor; load bus maximum capacity; load margin; maximum line transit capacity; voltage stability</dc:subject>
	<dc:description xml:lang="en-US">Achieving a balance between the satisfaction of energy requirements and adherence to environmental and social regulations stipulated in international agreements necessitates the rigorous management of existing electricity systems by electricity network operators, thereby ensuring that thermal and stability limits are not exceeded. Consequently, the assessment of load bus maximum capacity (LBMC) at any given load bus (LB) becomes imperative for ensuring the reliability and efficiency of electricity transmission networks. The extant literature on the subject of assessing LBMC in electrical networks either fails to take into account the combined effects on such networks of their various load points or, if it does, it is computationally intensive. The approach proposed in this paper involves a simplified method for assessing the LBMC for each of the LBs in the network. This is achieved to ensure that the combined effect of increasing the load on each of these buses does not compromise the load planning determined by a given network performance index, either during normal operation or in the event of a malfunction. The findings substantiate the efficacy of the proposed methodology, which facilitates the reliable estimation of LBMC. The reliability of this approach is ensured by the selection of a reliable performance indicator, which in our case is the complex stability index for transmission lines (CSITL).</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/22045</dc:identifier>
	<dc:identifier>10.11591/ijape.v15.i3.pp1105-1116</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 15, No 3: September 2026; 1105-1116</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v15.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/22045/13488</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Moussa Gonda, Arouna Oloulade, Richard Gilles Agbokpanzo, Maurel Richy Aza-Gnandji, Hassane Ousseyni Ibrahim, Cossi Télesphore Nounangnonhou, François-Xavier Fifatin, Adolphe Moukengue Imano</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>