Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Stable and robust control strategy using interval-valued fuzzy systems

International Journal of Applied Power Engineering (IJAPE) · Vol. 9 No. 3 (2020) · hlm. 205–217

DOI
10.11591/ijape.v9.i3.pp205-217
ISSN
2722-2624, 2252-8792
Terbit
2020-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In this paper we propose an adaptive interval valued fuzzy controller for high performance direct vector-controlled induction motor drive. Interval valued controller compared with type-1 fuzzy controller has the advantage that it can take into account the linguistic uncertainties present in the rules of the estimated models. The proposed control framework consists of a mixture of two controllers: an interval valued fuzzy controller and a supervisory controller. The supervisory controller is used when thesystem starts to become unstable. The free parameters for the proposed controller are changed according to some learning rules based on Lyapunov stability. Simulation results on an induction motor show the effectiveness ofthe introduced method.

Jaringan kolaborasi para penulis

13 penulis · 31 tautan kepenulisan bersama · 14 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Batna 2
  • University of Eloued
  • Centre Universitaire Morsli Abdellah de Tipaza
  • University of Biskra
  • Ahlia University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Souheib RemhaAfiliasi tidak diketahui1
Khaled MiloudiUniversity of Eloued1
Ala Eddine DjokhrabUniversity of Eloued1
Mosbah LaouamerUniversity of Eloued1
Yacine AounUniversity of Eloued1
Madina HamianeAhlia University1
Mohamed Tahar MakhloufiUniversity of Batna 21
Azzeddine YahiaUniversity of Batna 21
Nadjiba TerkiUniversity of Biskra1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Stable and robust control strategy using interval-valued fuzzy systems</dc:title>
	<dc:creator>Bounouara, Nadia</dc:creator>
	<dc:creator>Ghanai, Mouna</dc:creator>
	<dc:creator>Medjghou, Ali</dc:creator>
	<dc:creator>Chafaa, Kheireddine</dc:creator>
	<dc:description xml:lang="en-US">In this paper we propose an adaptive interval valued fuzzy controller for high performance direct vector-controlled induction motor drive. Interval valued controller compared with type-1 fuzzy controller has the advantage that it can take into account the linguistic uncertainties present in the rules of the estimated models. The proposed control framework consists of a mixture of two controllers: an interval valued fuzzy controller and a supervisory controller. The supervisory controller is used when thesystem starts to become unstable. The free parameters for the proposed controller are changed according to some learning rules based on Lyapunov stability. Simulation results on an induction motor show the effectiveness ofthe introduced method.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/19590</dc:identifier>
	<dc:identifier>10.11591/ijape.v9.i3.pp205-217</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 9, No 3: December 2020; 205-217</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v9.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/19590/12906</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>