In industrial applications, especially in manufacturing environments, electric motors are employed practically everywhere. They are necessary for many different sectors, which can sometimes make it challenging to prevent malfunctions and keep them operating at their best. Numerous defects can affect how well they work, but bearing-related errors are the most frequent reasons for motor failures. This research uses temporal and frequency domain analysis of vibration signals to identify motor faults. A public domain database has been used for the investigation and analysis. The findings show that electric motor problems, including inner raceway, outer raceway, and rolling element fault, can be identified and diagnosed using the time and frequency domain features extracted from the vibration signals. The effectiveness of the proposed technique is shown by comparing it with both the time domain and frequency domain techniques. The accuracy of the time domain and frequency domain techniques is 85.4% and 91.6% respectively. However, the proposed hybrid technique has a far better accuracy of 95.8% as compared to the two techniques.
Jaringan kolaborasi para penulis
4 penulis ·
4 tautan kepenulisan bersama
· 3 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Punjab Engineering College Thapar Institute of Engineering & Technology Guru Nanak Dev University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
Kavita Dhami Punjab Engineering College 1
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Fault diagnosis of electric motors using vibration signal analysis</dc:title>
<dc:creator>Singh, Mandeep</dc:creator>
<dc:creator>Saggu, Tejinder Singh</dc:creator>
<dc:creator>Dhingra, Arvind</dc:creator>
<dc:subject xml:lang="en-US">bearing faults; electric motors; frequency domain analysis; time domain analysis; vibration signals</dc:subject>
<dc:description xml:lang="en-US">In industrial applications, especially in manufacturing environments, electric motors are employed practically everywhere. They are necessary for many different sectors, which can sometimes make it challenging to prevent malfunctions and keep them operating at their best. Numerous defects can affect how well they work, but bearing-related errors are the most frequent reasons for motor failures. This research uses temporal and frequency domain analysis of vibration signals to identify motor faults. A public domain database has been used for the investigation and analysis. The findings show that electric motor problems, including inner raceway, outer raceway, and rolling element fault, can be identified and diagnosed using the time and frequency domain features extracted from the vibration signals. The effectiveness of the proposed technique is shown by comparing it with both the time domain and frequency domain techniques. The accuracy of the time domain and frequency domain techniques is 85.4% and 91.6% respectively. However, the proposed hybrid technique has a far better accuracy of 95.8% as compared to the two techniques.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2025-06-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21188</dc:identifier>
<dc:identifier>10.11591/ijape.v14.i2.pp300-307</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 2: June 2025; 300-307</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v14.i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21188/13311</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2025 Tejinder Singh</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Singh, M., Saggu, T. S., & Dhingra, A. (2025). Fault diagnosis of electric motors using vibration signal analysis. International Journal of Applied Power Engineering (IJAPE), 14(2), 300–307. https://doi.org/10.11591/ijape.v14.i2.pp300-307
Salin
IEEE
M. Singh, T. S. Saggu, and A. Dhingra, “Fault diagnosis of electric motors using vibration signal analysis,” International Journal of Applied Power Engineering (IJAPE), vol. 14, no. 2, pp. 300–307, 2025, doi: 10.11591/ijape.v14.i2.pp300-307.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.