Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Three-phase model of SCIG-based variable speed wind turbine for unbalanced DSLF analysis

International Journal of Applied Power Engineering (IJAPE) · Vol. 13 No. 2 (2024) · hlm. 351–361

DOI
10.11591/ijape.v13.i2.pp351-361
ISSN
2722-2624, 2252-8792
Terbit
2024-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Steady state performances of the electric power distribution system are normally assessed or evaluated based on load flow analysis. To properly carry out the analysis, a valid steady state load flow model of each distribution system component, including the wind power plant (WPP), needs to be developed. The present paper proposes a method for modeling and integrating squirrel cage induction generator (SCIG)-based variable speed WPP into a three-phase unbalanced distribution system load flow (DSLF) analysis. The proposed method is based on a single-phase T-circuit model of fixed speed WPP, which has successfully been applied to balanced electric power systems. In the present work, the single-phase T-circuit model is extended and modified to be used in steady state load flow analysis of three-phase unbalanced distribution systems embedded with SCIG-based variable speed WPP. Results of the case studies confirm the validity of the proposed method.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 32 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tanjungpura University
  • Universitas Muhammadiyah Sumatera Utara
  • Universiti Malaysia Perlis
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ayong HiendroTanjungpura University5
Kho Hie KhweeTanjungpura University3
F. Trias Pontia WigyariantoTanjungpura University2
Junaidi JunaidiTanjungpura University2
Fitriah HusinAfiliasi tidak diketahui1
Purwoharjono PurwoharjonoTanjungpura University1
M. Iqbal ArsyadTanjungpura University1
Managam RajagukgukTanjungpura University1
Trias Pontia WigyariantoTanjungpura University1
Yohannes M SimanjuntakTanjungpura University1
Muhammad IrwantoUniversiti Malaysia Perlis1
Suwarno SuwarnoUniversitas Muhammadiyah Sumatera Utara1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Three-phase model of SCIG-based variable speed wind turbine for unbalanced DSLF analysis</dc:title>
	<dc:creator>Yusuf, Ismail</dc:creator>
	<dc:creator>Gianto, Rudy</dc:creator>
	<dc:subject xml:lang="en-US">load flow; SCIG; unbalanced distribution system; variable speed; wind turbine generator</dc:subject>
	<dc:description xml:lang="en-US">Steady state performances of the electric power distribution system are normally assessed or evaluated based on load flow analysis. To properly carry out the analysis, a valid steady state load flow model of each distribution system component, including the wind power plant (WPP), needs to be developed. The present paper proposes a method for modeling and integrating squirrel cage induction generator (SCIG)-based variable speed WPP into a three-phase unbalanced distribution system load flow (DSLF) analysis. The proposed method is based on a single-phase T-circuit model of fixed speed WPP, which has successfully been applied to balanced electric power systems. In the present work, the single-phase T-circuit model is extended and modified to be used in steady state load flow analysis of three-phase unbalanced distribution systems embedded with SCIG-based variable speed WPP. Results of the case studies confirm the validity of the proposed method.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20938</dc:identifier>
	<dc:identifier>10.11591/ijape.v13.i2.pp351-361</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 13, No 2: June 2024; 351-361</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v13.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20938/13195</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Ismail Yusuf, Rudy Gianto</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>