Akses terbuka
Jurnal
SINTA 1
A multi-scale dual-stage model for PV array fault detection, classification, and monitoring technique
International Journal of Applied Power Engineering (IJAPE) · Vol. 11 No. 2 (2022) · hlm. 134–144
ISSN 2722-2624, 2252-8792
Terbit 2022-06-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
The output generated by photovoltaic arrays is influenced mainly by the irradiance, which has non-uniform distribution in a day. This has resulted in the current-limiting nature and nonlinear output characteristics, and conventional protection devices cannot detect and clean faults appropriately. This paper proposes a low-cost model for a multi-scale dual-stage photovoltaic fault detection, classification, and monitoring technique developed through MATLAB/Simulink. The main contribution of this paper is that it can detect multiple common faults, be applied on multi-scale photovoltaic arrays regardless of environmental conditions, and be beneficial for photovoltaic system maintenance work. The experimental results show that the developed algorithm using supervised learning algorithms mutual with k-fold cross-validation has produced good performances in identifying six common faults of photovoltaic arrays, achieved 100% accuracy in fault detection, and achieved good accuracy in fault classification. Challenges and suggestions for future research direction are also suggested in this paper. Overall, this study shall provide researchers and policymakers with a valuable reference for developing photovoltaic system fault detection and monitoring techniques for better feasibility, safety, and energy sustainability.
Jaringan kolaborasi para penulis
8 penulis ·
22 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universiti Malaysia Pahang Al-Sultan Abdullah
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">A multi-scale dual-stage model for PV array fault detection, classification, and monitoring technique</dc:title>
<dc:creator>Ghazali, Siti Nor Azlina Mohd</dc:creator>
<dc:creator>Sujod, Muhamad Zahim</dc:creator>
<dc:subject xml:lang="en-US">discriminate analysis; fault detection; K-fold cross-validation; K-nearest neighbor; random forest; solar photovoltaic; support vector machine</dc:subject>
<dc:description xml:lang="en-US">The output generated by photovoltaic arrays is influenced mainly by the irradiance, which has non-uniform distribution in a day. This has resulted in the current-limiting nature and nonlinear output characteristics, and conventional protection devices cannot detect and clean faults appropriately. This paper proposes a low-cost model for a multi-scale dual-stage photovoltaic fault detection, classification, and monitoring technique developed through MATLAB/Simulink. The main contribution of this paper is that it can detect multiple common faults, be applied on multi-scale photovoltaic arrays regardless of environmental conditions, and be beneficial for photovoltaic system maintenance work. The experimental results show that the developed algorithm using supervised learning algorithms mutual with k-fold cross-validation has produced good performances in identifying six common faults of photovoltaic arrays, achieved 100% accuracy in fault detection, and achieved good accuracy in fault classification. Challenges and suggestions for future research direction are also suggested in this paper. Overall, this study shall provide researchers and policymakers with a valuable reference for developing photovoltaic system fault detection and monitoring techniques for better feasibility, safety, and energy sustainability.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US">Universiti Malaysia Pahang, Malaysia</dc:contributor>
<dc:date>2022-06-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20480</dc:identifier>
<dc:identifier>10.11591/ijape.v11.i2.pp134-144</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 11, No 2: June 2022; 134-144</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v11.i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20480/12996</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Siti Nor Azlina Mohd Ghazali, Muhamad Zahim Sujod</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Ghazali, S. N. A. M., & Sujod, M. Z. (2022). A multi-scale dual-stage model for PV array fault detection, classification, and monitoring technique. International Journal of Applied Power Engineering (IJAPE), 11(2), 134–144. https://doi.org/10.11591/ijape.v11.i2.pp134-144
Salin
IEEE
S. N. A. M. Ghazali and M. Z. Sujod, “A multi-scale dual-stage model for PV array fault detection, classification, and monitoring technique,” International Journal of Applied Power Engineering (IJAPE), vol. 11, no. 2, pp. 134–144, 2022, doi: 10.11591/ijape.v11.i2.pp134-144.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.