Akses terbuka
Jurnal
SINTA 1
Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Under Transient Conditions
International Journal of Applied Power Engineering (IJAPE) · Vol. 3 No. 2 (2014) · hlm. 90–104
ISSN 2722-2624, 2252-8792
Terbit 2014-08-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
Frequency dependence complete model is set up for describing the lightning transient behavior of the wind turbines (WTs).To get an appropriate wind turbine model, a high frequency models of surge arrester protecting the boost transformer, transformer and ground electrode soil ionization are implemented. The transient responses and Ground Potential Rise (GPR) can be obtained at different locations in the WTs and connected grid in the time domain as well as in the frequency domain using Fast Fourier Transform (FFT). To check the validity of the model, Surge arresters protection level at different locations, at i.e. LV, MV and HV, is compared with ABB manufacture data sheet, Also a comparison has been made between simple and frequency dependence model of overall wind farm components using ATP/EMTP. This paper provides an accurate simulation of wind farm components under transient condition.
Jaringan kolaborasi para penulis
7 penulis ·
10 tautan kepenulisan bersama
· 2 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Benha University Egyptian Russian University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Under Transient Conditions</dc:title>
<dc:creator>Abd-Allah, M. A.</dc:creator>
<dc:creator>Ali, Mahmoud N.</dc:creator>
<dc:creator>Said, A.</dc:creator>
<dc:subject xml:lang="en-US">WTs, surge arrester model, transient response, GPR, FFT, ATP/EMTP</dc:subject>
<dc:description xml:lang="en-US">Frequency dependence complete model is set up for describing the lightning transient behavior of the wind turbines (WTs).To get an appropriate wind turbine model, a high frequency models of surge arrester protecting the boost transformer, transformer and ground electrode soil ionization are implemented. The transient responses and Ground Potential Rise (GPR) can be obtained at different locations in the WTs and connected grid in the time domain as well as in the frequency domain using Fast Fourier Transform (FFT). To check the validity of the model, Surge arresters protection level at different locations, at i.e. LV, MV and HV, is compared with ABB manufacture data sheet, Also a comparison has been made between simple and frequency dependence model of overall wind farm components using ATP/EMTP. This paper provides an accurate simulation of wind farm components under transient condition.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2014-08-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/1326</dc:identifier>
<dc:identifier>10.11591/ijape.v3.i2.pp90-104</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 3, No 2: August 2014; 90-104</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v3.i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/1326/4119</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat DOI
10 sitasi
Crossref
Tidak ditemukan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
Sitasi artikel ini
APA 7
Abd-Allah, M. A., Ali, M. N., & Said, A. (2014). Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Under Transient Conditions. International Journal of Applied Power Engineering (IJAPE), 3(2), 90–104. https://doi.org/10.11591/ijape.v3.i2.pp90-104
Salin
IEEE
M. A. Abd-Allah, M. N. Ali, and A. Said, “Towards An Accurate Modeling of Frequency-dependent Wind Farm Components Under Transient Conditions,” International Journal of Applied Power Engineering (IJAPE), vol. 3, no. 2, pp. 90–104, 2014, doi: 10.11591/ijape.v3.i2.pp90-104.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.