Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparative analysis of two static var compensator models in voltage control of transmission network

International Journal of Applied Power Engineering (IJAPE) · Vol. 13 No. 4 (2024) · hlm. 920–927

DOI
10.11591/ijape.v13.i4.pp920-927
ISSN
2722-2624, 2252-8792
Terbit
2024-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The static var compensator (SVC) is a member of the family of flexible alternating current transmission systems controllers used in power system engineering to manage specific transmission network characteristics to enhance the performance of the transmission networks and thus increase the networks’ reliability. Power system engineers typically find it difficult to choose which SVC model to implement for simulations. This research aims to address this issue by conducting a comparative examination of two key SVC models on a transmission network. The two models of SVC variable shunt susceptance and firing angle were mathematically modeled and methodically included into the Newton-Raphson power flow algorithm for the network power flow solution. The IEEE 30-bus network was adopted as the test case, and the method was implemented in the MATLAB/Simulink environment. The network performance metric utilized was the voltage profile of the network. The two SVC models were successful in enhancing the network's performance; however, the variable shunt susceptance model was computationally faster than the firing angle model, as revealed by the simulation results. Therefore, among the two SVC models, the variable shunt susceptance model may be taken into account for simulation to enhance the performance of the transmission networks.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 36 tautan kepenulisan bersama · 28 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Obafemi Awolowo University
  • Lead City University
  • University of Ilorin
  • Cape Peninsula University of Technology
  • Ladoke Akintola University of Technology
  • Olabisi Onabanjo University
  • Kwara State University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Abdulsamad Bolakale JimohUniversity of Ilorin8
Adedire Ayodeji BabatundeOlabisi Onabanjo University3
Fatina Mosunmola AremuKwara State University3
Emmanuel Idowu OgunwoleCape Peninsula University of Technology2
Abdullahi AremuAfiliasi tidak diketahui2
Dolapo Eniola OwolabiLadoke Akintola University of Technology2
Ayodeji Olalekan SalauAfe Babalola University1
Sepiribo Lucky BraideRivers State University1
Tayo Uthman BadrudeenOduduwa University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparative analysis of two static var compensator models in voltage control of transmission network</dc:title>
	<dc:creator>Jimoh, Abdulrasaq</dc:creator>
	<dc:creator>Ayanlade, Samson Oladayo</dc:creator>
	<dc:creator>Ariyo, Funso Kehinde</dc:creator>
	<dc:creator>Adebayo, Moses Taiwo</dc:creator>
	<dc:subject xml:lang="en-US">FACTS devices; firing angle; static var compensator; variable susceptance; voltage regulation</dc:subject>
	<dc:description xml:lang="en-US">The static var compensator (SVC) is a member of the family of flexible alternating current transmission systems controllers used in power system engineering to manage specific transmission network characteristics to enhance the performance of the transmission networks and thus increase the networks’ reliability. Power system engineers typically find it difficult to choose which SVC model to implement for simulations. This research aims to address this issue by conducting a comparative examination of two key SVC models on a transmission network. The two models of SVC variable shunt susceptance and firing angle were mathematically modeled and methodically included into the Newton-Raphson power flow algorithm for the network power flow solution. The IEEE 30-bus network was adopted as the test case, and the method was implemented in the MATLAB/Simulink environment. The network performance metric utilized was the voltage profile of the network. The two SVC models were successful in enhancing the network's performance; however, the variable shunt susceptance model was computationally faster than the firing angle model, as revealed by the simulation results. Therefore, among the two SVC models, the variable shunt susceptance model may be taken into account for simulation to enhance the performance of the transmission networks.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21175</dc:identifier>
	<dc:identifier>10.11591/ijape.v13.i4.pp920-927</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 13, No 4: December 2024; 920-927</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v13.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21175/13269</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Abdulrasaq Jimoh, Samson Oladayo Ayanlade, Funso Kehinde Ariyo, Moses Taiwo Adebayo</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>