Abstrak
Ensuring reliable fault diagnosis and rapid recovery in distributed generator (DG)-connected distribution systems is critical, as the integration of DG sources significantly elevates fault current levels. This study proposes an integrated approach that combines a resistive superconducting fault current limiter (RSFCL) with an artificial neural network (ANN)-based intelligent fault diagnosis framework. The objective is to limit excessive fault currents while improving detection accuracy under varying network configurations. The RSFCL is strategically placed by analyzing fault current magnitude, voltage quality, and resistance value to achieve effective current limitation without compromising system stability. Meanwhile, the ANN employs symmetrical components of current and voltage as diagnostic features. To enhance robustness, correlated variables are identified and eliminated during feature selection, strengthening the model’s fault discrimination capability. Simulation results demonstrate that the optimal RSFCL placement reduces fault current contribution ratios by up to 82.16% under symmetrical fault conditions. The ANN-based fault detection model achieves a validation accuracy of 99.7%, outperforming conventional threshold-based methods by minimizing nuisance tripping and improving circuit breaker coordination. Overall, the combined RSFCL–ANN framework provides an effective and intelligent solution for fault diagnosis and protection in DG-integrated power systems.
Jaringan kolaborasi para penulis
4 penulis ·
5 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Amrita Vishwa Vidyapeetham Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
K. Rakhi Afiliasi tidak diketahui 2
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Intelligent fault diagnosis and protection in DG-connected systems using resistive superconducting fault current limiter and ANN-based detection</dc:title>
<dc:creator>Chandran, Lekshmi R.</dc:creator>
<dc:creator>Karuppasamy, Ilango</dc:creator>
<dc:creator>Nair, Manjula G.</dc:creator>
<dc:subject xml:lang="en-US">artificial neural network; distributed generation; fault diagnosis; superconducting fault current limiter; symmetrical components</dc:subject>
<dc:description xml:lang="en-US">Ensuring reliable fault diagnosis and rapid recovery in distributed generator (DG)-connected distribution systems is critical, as the integration of DG sources significantly elevates fault current levels. This study proposes an integrated approach that combines a resistive superconducting fault current limiter (RSFCL) with an artificial neural network (ANN)-based intelligent fault diagnosis framework. The objective is to limit excessive fault currents while improving detection accuracy under varying network configurations. The RSFCL is strategically placed by analyzing fault current magnitude, voltage quality, and resistance value to achieve effective current limitation without compromising system stability. Meanwhile, the ANN employs symmetrical components of current and voltage as diagnostic features. To enhance robustness, correlated variables are identified and eliminated during feature selection, strengthening the model’s fault discrimination capability. Simulation results demonstrate that the optimal RSFCL placement reduces fault current contribution ratios by up to 82.16% under symmetrical fault conditions. The ANN-based fault detection model achieves a validation accuracy of 99.7%, outperforming conventional threshold-based methods by minimizing nuisance tripping and improving circuit breaker coordination. Overall, the combined RSFCL–ANN framework provides an effective and intelligent solution for fault diagnosis and protection in DG-integrated power systems.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2026-09-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21944</dc:identifier>
<dc:identifier>10.11591/ijape.v15.i3.pp1009-1022</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 15, No 3: September 2026; 1009-1022</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v15.i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21944/13481</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 Lekshmi R. Chandran, Ilango Karuppasamy, Manjula G. Nair</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Chandran, L. R., Karuppasamy, I., & Nair, M. G. (2026). Intelligent fault diagnosis and protection in DG-connected systems using resistive superconducting fault current limiter and ANN-based detection. International Journal of Applied Power Engineering (IJAPE), 15(3), 1009–1022. https://doi.org/10.11591/ijape.v15.i3.pp1009-1022
Salin
IEEE
L. R. Chandran, I. Karuppasamy, and M. G. Nair, “Intelligent fault diagnosis and protection in DG-connected systems using resistive superconducting fault current limiter and ANN-based detection,” International Journal of Applied Power Engineering (IJAPE), vol. 15, no. 3, pp. 1009–1022, 2026, doi: 10.11591/ijape.v15.i3.pp1009-1022.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.