Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparative analysis of THD for square-wave inverter at different conduction modes

International Journal of Applied Power Engineering (IJAPE) · Vol. 12 No. 3 (2023) · hlm. 312–320

DOI
10.11591/ijape.v12.i3.pp312-320
ISSN
2722-2624, 2252-8792
Terbit
2023-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper proposes conduction schemes for the most common six-switch voltage sources inverter. Also, a comparative study of the output THD for different conduction modes of switches for a three-phase square wave inverter is done, as the harmonic content of any electrical system is important to analyze its performance. The harmonic distortion of the load voltage and load current is taken as the main constraint to evaluate the performance of the three-phase inverter. So, control strategies for various loads are executed for different modulation schemes of inverter switches using MATLAB/Simulink software. Obtained results show that 150° conduction gives the least THD for output current, and 170° conduction gives the least THD for output voltage for three-phase inverters. Also, harmonic contents are reduced using a passive LC filter at the output of the inverter.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Madan Mohan Malaviya University of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Khadim Moin SiddiquiAfiliasi tidak diketahui1
V. K. GiriMadan Mohan Malaviya University of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparative analysis of THD for square-wave inverter at different conduction modes</dc:title>
	<dc:creator>Gupta, Ranitesh</dc:creator>
	<dc:creator>Sahay, Kuldeep</dc:creator>
	<dc:subject xml:lang="en-US">conduction mode; harmonics; square-wave inverter; total harmonic distortion; voltage source inverter</dc:subject>
	<dc:description xml:lang="en-US">This paper proposes conduction schemes for the most common six-switch voltage sources inverter. Also, a comparative study of the output THD for different conduction modes of switches for a three-phase square wave inverter is done, as the harmonic content of any electrical system is important to analyze its performance. The harmonic distortion of the load voltage and load current is taken as the main constraint to evaluate the performance of the three-phase inverter. So, control strategies for various loads are executed for different modulation schemes of inverter switches using MATLAB/Simulink software. Obtained results show that 150° conduction gives the least THD for output current, and 170° conduction gives the least THD for output voltage for three-phase inverters. Also, harmonic contents are reduced using a passive LC filter at the output of the inverter.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2023-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20616</dc:identifier>
	<dc:identifier>10.11591/ijape.v12.i3.pp312-320</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 12, No 3: September 2023; 312-320</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v12.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20616/13078</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Ranitesh Gupta, Kuldeep Sahay</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>