Akses terbuka
Jurnal
SINTA 1
Utilization of BSA optimized cascade controller in a renewable energy-based AGC systems
International Journal of Applied Power Engineering (IJAPE) · Vol. 15 No. 2 (2026) · hlm. 546–553
ISSN 2722-2624, 2252-8792
Terbit 2026-06-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
A novel cascade controller named proportional integral derivative-tilt integral derivative (PID-TID) is proposed for a two-area thermal-wind automatic generation control (AGC) system and its gains are optimized by a novel metaheuristic bird swarm algorithm (BSA). The BSA tuned PID-TID controller enhances dynamics over PID and TID controller in terms of settling time and peak shoots. Moreover, dynamics with wind integration have shown significant improvement over thermal system alone. Further system has shown enhanced dynamics with redox flow batteries (RFB) over thermal-wind system. Furthermore, studies with automatic voltage regulation (AVR) strengthen voltage stability. Also, responses with PID-TID have shown steady dynamic profile at various loading conditions. Integrating wind energy into thermal system results in significant enhancements in dynamics showcasing greater stability. Also, improvements are evident with the RFB introduction, enhance dynamic with in hybrid system. The incorporation of AVR enhance voltage stability. The proposed PID-TID demonstrates significant robustness ensuring stable response under loading condition and effectively boost dynamic performance.
Jaringan kolaborasi para penulis
7 penulis ·
16 tautan kepenulisan bersama
· 5 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Aditya University Andhra University Symbiosis International University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Utilization of BSA optimized cascade controller in a renewable energy-based AGC systems</dc:title>
<dc:creator>Kasukurthi, Rambabu</dc:creator>
<dc:creator>Naik, R. Srinu</dc:creator>
<dc:subject xml:lang="en-US">automatic generation control; automatic voltage regulation; bird swarm algorithm; PID-TID controller; wind turbine systems</dc:subject>
<dc:description xml:lang="en-US">A novel cascade controller named proportional integral derivative-tilt integral derivative (PID-TID) is proposed for a two-area thermal-wind automatic generation control (AGC) system and its gains are optimized by a novel metaheuristic bird swarm algorithm (BSA). The BSA tuned PID-TID controller enhances dynamics over PID and TID controller in terms of settling time and peak shoots. Moreover, dynamics with wind integration have shown significant improvement over thermal system alone. Further system has shown enhanced dynamics with redox flow batteries (RFB) over thermal-wind system. Furthermore, studies with automatic voltage regulation (AVR) strengthen voltage stability. Also, responses with PID-TID have shown steady dynamic profile at various loading conditions. Integrating wind energy into thermal system results in significant enhancements in dynamics showcasing greater stability. Also, improvements are evident with the RFB introduction, enhance dynamic with in hybrid system. The incorporation of AVR enhance voltage stability. The proposed PID-TID demonstrates significant robustness ensuring stable response under loading condition and effectively boost dynamic performance.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2026-06-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21878</dc:identifier>
<dc:identifier>10.11591/ijape.v15.i2.pp546-553</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 15, No 2: June 2026; 546-553</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v15.i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21878/13440</dc:relation>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/downloadSuppFile/21878/3160</dc:relation>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/downloadSuppFile/21878/3194</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2026 Rambabu Kasukurthi, R. Srinu Naik</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Kasukurthi, R., & Naik, R. S. (2026). Utilization of BSA optimized cascade controller in a renewable energy-based AGC systems. International Journal of Applied Power Engineering (IJAPE), 15(2), 546–553. https://doi.org/10.11591/ijape.v15.i2.pp546-553
Salin
IEEE
R. Kasukurthi and R. S. Naik, “Utilization of BSA optimized cascade controller in a renewable energy-based AGC systems,” International Journal of Applied Power Engineering (IJAPE), vol. 15, no. 2, pp. 546–553, 2026, doi: 10.11591/ijape.v15.i2.pp546-553.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.