Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dynamic Voltage Restorer

International Journal of Applied Power Engineering (IJAPE) · Vol. 1 No. 3 (2012) · hlm. 129–144

DOI
10.11591/ijape.v1.i3.pp129-144
ISSN
2722-2624, 2252-8792
Terbit
2012-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

DVR is a equipment which was connected in series and adjusting the loading voltage by feeding the voltage in system. The first installation was in 1996. usually DVR installed between sensitive loads feeder and source in distribution system.The main duty, fast support load voltage (by fast detection algorithm) during disturbance to avoid any disconnection. in this paper approaches to compensate for voltage sag and swell as a common disturbance in voltage transmission and distribution networks is presented. A dynamic voltage restorer based on the dq0 algorithm for three-phase and dynamic voltage restorer based on the average detection method for single-phase are discussed, also in this paper we compare the two methods used to compensate the single-phase and three-phase process. result of three-phase and single-phase voltage sag and swell simulation has been presented by MATLAB/SIMULINK.

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 8 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Imam Khomeini International University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Masoud SafariAfiliasi tidak diketahui1
S. M. TorabiAfiliasi tidak diketahui1
Iman SoltaniImam Khomeini International University1
Hossein FaramarziImam Khomeini International University1
Majid KeshmiriAfiliasi tidak diketahui1
Majid SalimAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dynamic Voltage Restorer</dc:title>
	<dc:creator>Marefatjou, Haniyeh</dc:creator>
	<dc:creator>Sarvi, Mohammad</dc:creator>
	<dc:subject xml:lang="en-US">Voltage sag Voltage Swell  Fast detection algorithm Average detection method DVR</dc:subject>
	<dc:description xml:lang="en-US">DVR is a equipment which was connected in series and adjusting the  loading  voltage  by  feeding  the  voltage  in  system. The  first  installation  was  in 1996. usually DVR  installed  between  sensitive loads feeder and  source in distribution system .The  main  duty, fast support load voltage  (by  fast  detection  algorithm)  during  disturbance  to  avoid  any  disconnection. in this paper approaches to compensate for voltage sag and swell as a common disturbance in voltage transmission and distribution networks is presented. A dynamic voltage restorer based on the dq0 algorithm for three-phase and dynamic voltage restorer based on the average detection method for single-phase are discussed, also in this paper we compare the two methods used to compensate the single-phase and three-phase process. result  of   three-phase and single-phase voltage sag and swell  simulation  has  been  presented  by  MATLAB/SIMULINK.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2012-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/1293</dc:identifier>
	<dc:identifier>10.11591/ijape.v1.i3.pp129-144</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 1, No 3: December 2012; 129-144</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v1.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/1293/737</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>