Akses terbuka
Jurnal
SINTA 1
Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dynamic Voltage Restorer
International Journal of Applied Power Engineering (IJAPE) · Vol. 1 No. 3 (2012) · hlm. 129–144
ISSN 2722-2624, 2252-8792
Terbit 2012-12-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
DVR is a equipment which was connected in series and adjusting the loading voltage by feeding the voltage in system. The first installation was in 1996. usually DVR installed between sensitive loads feeder and source in distribution system.The main duty, fast support load voltage (by fast detection algorithm) during disturbance to avoid any disconnection. in this paper approaches to compensate for voltage sag and swell as a common disturbance in voltage transmission and distribution networks is presented. A dynamic voltage restorer based on the dq0 algorithm for three-phase and dynamic voltage restorer based on the average detection method for single-phase are discussed, also in this paper we compare the two methods used to compensate the single-phase and three-phase process. result of three-phase and single-phase voltage sag and swell simulation has been presented by MATLAB/SIMULINK.
Jaringan kolaborasi para penulis
8 penulis ·
8 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Imam Khomeini International University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dynamic Voltage Restorer</dc:title>
<dc:creator>Marefatjou, Haniyeh</dc:creator>
<dc:creator>Sarvi, Mohammad</dc:creator>
<dc:subject xml:lang="en-US">Voltage sag Voltage Swell Fast detection algorithm Average detection method DVR</dc:subject>
<dc:description xml:lang="en-US">DVR is a equipment which was connected in series and adjusting the loading voltage by feeding the voltage in system. The first installation was in 1996. usually DVR installed between sensitive loads feeder and source in distribution system .The main duty, fast support load voltage (by fast detection algorithm) during disturbance to avoid any disconnection. in this paper approaches to compensate for voltage sag and swell as a common disturbance in voltage transmission and distribution networks is presented. A dynamic voltage restorer based on the dq0 algorithm for three-phase and dynamic voltage restorer based on the average detection method for single-phase are discussed, also in this paper we compare the two methods used to compensate the single-phase and three-phase process. result of three-phase and single-phase voltage sag and swell simulation has been presented by MATLAB/SIMULINK.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2012-12-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/1293</dc:identifier>
<dc:identifier>10.11591/ijape.v1.i3.pp129-144</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 1, No 3: December 2012; 129-144</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v1.i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/1293/737</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Belum diperiksa
Crossref
Terindeks
lewat Judul + tahun
2 sitasi
Jumlah menurut tiap indeks pada 9 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
Sitasi artikel ini
APA 7
Marefatjou, H., & Sarvi, M. (2012). Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dynamic Voltage Restorer. International Journal of Applied Power Engineering (IJAPE), 1(3), 129–144. https://doi.org/10.11591/ijape.v1.i3.pp129-144
Salin
IEEE
H. Marefatjou and M. Sarvi, “Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dynamic Voltage Restorer,” International Journal of Applied Power Engineering (IJAPE), vol. 1, no. 3, pp. 129–144, 2012, doi: 10.11591/ijape.v1.i3.pp129-144.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.