Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Transmission line fault detection using empirical mode decomposition in presence of wind intermittency

International Journal of Applied Power Engineering (IJAPE) · Vol. 14 No. 4 (2025) · hlm. 960–969

DOI
10.11591/ijape.v14.i4.pp960-969
ISSN
2722-2624, 2252-8792
Terbit
2025-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The regular fault detection approaches are failed to detect the faults in wind integrated transmission networks due to intermittency nature of the wind energy. More reliable schemes are required to accomplish the detection of faults in presence wind. This article proposed empirical mode decomposition (EMD) based fault detection scheme to detect various faults in wind integrated transmission lines during the normal and stressed conditions of the system. The instantaneous current measurements available at either sending or receiving end are processed through EMD to decompose it into a series of intrinsic mode functions (IMFs) and IMF2 is identified as a dominated IMF with numerous case wise investigations. 1/4th cycle moving window is used to calculate the absolute sum of the IMF2 coefficients to detect the faults with the support of a predefined threshold. The efficacy of the method is tested on different types of faults during the normal condition in presence of wind and later extended to stressed conditions such as power swing. The method is reliable during the typical cases and includes remote end and high resistance faults. All the experiments are carried out in Simulink to generate the measurement data and programs are executed in MATLAB.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 24 tautan kepenulisan bersama · 14 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Annamalai University
  • King Khalid University
  • SRKR Engineering College
  • Acharya Nagarjuna University
  • Jawaharlal Nehru Technological University Anantapur
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ch. Ravi KumarAcharya Nagarjuna University1
Syed SurayaJawaharlal Nehru Technological University Anantapur1
Kukkamalla Kiran KumarAnnamalai University1
Kanta Rao PedakotaAfiliasi tidak diketahui1
Gobinathan BalajiAnnamalai University1
Yousef AsiriKing Khalid University1
Saad F. Al‐GahtaniKing Khalid University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Transmission line fault detection using empirical mode decomposition in presence of wind intermittency</dc:title>
	<dc:creator>Bokka, Venkata Krishna</dc:creator>
	<dc:creator>Biju, E. R.</dc:creator>
	<dc:creator>Mortha, Sai Veerraju</dc:creator>
	<dc:creator>Mahammad, Majahar Hussain</dc:creator>
	<dc:creator>Irshad, Shaik Mohammad</dc:creator>
	<dc:subject xml:lang="en-US">empirical mode decomposition; fault detection; faults; protection; wind</dc:subject>
	<dc:description xml:lang="en-US">The regular fault detection approaches are failed to detect the faults in wind integrated transmission networks due to intermittency nature of the wind energy. More reliable schemes are required to accomplish the detection of faults in presence wind. This article proposed empirical mode decomposition (EMD) based fault detection scheme to detect various faults in wind integrated transmission lines during the normal and stressed conditions of the system. The instantaneous current measurements available at either sending or receiving end are processed through EMD to decompose it into a series of intrinsic mode functions (IMFs) and IMF2 is identified as a dominated IMF with numerous case wise investigations. 1/4th cycle moving window is used to calculate the absolute sum of the IMF2 coefficients to detect the faults with the support of a predefined threshold. The efficacy of the method is tested on different types of faults during the normal condition in presence of wind and later extended to stressed conditions such as power swing. The method is reliable during the typical cases and includes remote end and high resistance faults. All the experiments are carried out in Simulink to generate the measurement data and programs are executed in MATLAB.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21691</dc:identifier>
	<dc:identifier>10.11591/ijape.v14.i4.pp960-969</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 4: December 2025; 960-969</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v14.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21691/13377</dc:relation>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/downloadSuppFile/21691/3104</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Venkata Krishna Bokka, E. R. Biju, Sai Veerraju Mortha, Majahar Hussain Mahammad, Shaik Mohammad Irshad</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>