Abstrak

Achieving energy efficiency and establishing energy conservation for driving future energy is one of the prime concerns of any nation. Besides, the lighting system, one of the major contributors of energy consumption set ahead in fixing the aforesaid concerns to the extent possible. When looking at environmental benefits and energy saving opportunities, among several available luminaries, LEDs stand far superior to standard tubular fluorescent lamps (TFL). However, the power consumption pattern differs by its manufacturing constraints which are notified to the consumers through the star ratings and energy efficiency labels. Energy savings can be achieved by systematically replacing the conventional TFLs by means of energy efficient LED lamps (EEL). This paper focuses on the practicality of use concerning the scheme of lamp replacement to achieve better energy efficiency. To carry out these isometrics, Bureau of Energy Efficiency (BEE) approved TFL and LED lamps of different brands and star ratings were used. In line with methodology discussed in the manuscript, it is obvious that by replacing 36 W and 28 W standard TFLs through appropriate EELs, the respective annual energy savings of about 11-16 kWh and 7 kWh can be achieved. The results highlight that replacing the lamps randomly can be futile; however, a strategic process in the selection and proximate replacement ensures an optimal level of efficiency. This leads to an increased lumen output, longer lamp life, or both, which ultimately saves an appreciable amount of energy. The prospective research may focus on inter EEL replacement isometrics to achieve microtic energy efficiency.

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 22 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • GMR Institute of Technology
  • Jawaharlal Nehru Technological University Anantapur
  • Sri Venkateswara College of Engineering Tirupati
  • Vallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology
  • Aditya Institute of Technology and Management
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kalyana Kiran KumarAditya Institute of Technology and Management1
Vasupalli ManojGMR Institute of Technology1
Malleti SreedharVallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology1
Rebba SasidharAfiliasi tidak diketahui1
Ramana PillaGMR Institute of Technology1
Tentu Papi NaiduAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Systematic lamp replacement for energy efficiency improvement: a comparative luminous-efficacy analysis</dc:title>
	<dc:creator>Jayachandra, S.</dc:creator>
	<dc:creator>Kiran, Shaik Rafi</dc:creator>
	<dc:subject xml:lang="en-US">energy efficiency; energy savings; lamp replacement strategy; LED lighting;  lumen output; sustainable lighting; tubular fluorescent lamps</dc:subject>
	<dc:description xml:lang="en-US">Achieving energy efficiency and establishing energy conservation for driving future energy is one of the prime concerns of any nation. Besides, the lighting system, one of the major contributors of energy consumption set ahead in fixing the aforesaid concerns to the extent possible. When looking at environmental benefits and energy saving opportunities, among several available luminaries, LEDs stand far superior to standard tubular fluorescent lamps (TFL). However, the power consumption pattern differs by its manufacturing constraints which are notified to the consumers through the star ratings and energy efficiency labels. Energy savings can be achieved by systematically replacing the conventional TFLs by means of energy efficient LED lamps (EEL). This paper focuses on the practicality of use concerning the scheme of lamp replacement to achieve better energy efficiency. To carry out these isometrics, Bureau of Energy Efficiency (BEE) approved TFL and LED lamps of different brands and star ratings were used. In line with methodology discussed in the manuscript, it is obvious that by replacing 36 W and 28 W standard TFLs through appropriate EELs, the respective annual energy savings of about 11-16 kWh and 7 kWh can be achieved. The results highlight that replacing the lamps randomly can be futile; however, a strategic process in the selection and proximate replacement ensures an optimal level of efficiency. This leads to an increased lumen output, longer lamp life, or both, which ultimately saves an appreciable amount of energy. The prospective research may focus on inter EEL replacement isometrics to achieve microtic energy efficiency.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/22179</dc:identifier>
	<dc:identifier>10.11591/ijape.v15.i3.pp1275-1286</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 15, No 3: September 2026; 1275-1286</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v15.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/22179/13503</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 S. Jayachandra, Shaik Rafi Kiran</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>