Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Improve the thermal performance of the combined water-paraffin hot storage tank in the absorption cooling cycle

International Journal of Applied Power Engineering (IJAPE) · Vol. 14 No. 4 (2025) · hlm. 1011–1022

DOI
10.11591/ijape.v14.i4.pp1011-1022
ISSN
2722-2624, 2252-8792
Terbit
2025-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This research investigates the thermal performance of storage materials in a hot tank designed to extend the operation time of a 1.5-ton water ammonia absorption cooling system. Thermal energy is supplied by concentric parabolic solar collectors, which heat the absorption cycle generator during periods of sufficient solar radiation. When the water temperature exceeds the system’s operating threshold, the additional heat accumulates in the hot tank. It is later used to drive the generator during periods of low solar availability, such as in the afternoon or after sunset. The system is designed to provide air conditioning for a room; its load was calculated hourly. The suitable size of the storage tank and the corresponding collector area were determined based on simulations of the absorption system to achieve an optimal coefficient of performance (COP). The collector area was increased after the addition of paraffin phase change material (PCM) to enhance system performance, and a temperature control strategy was implemented to prevent the water in the hot storage tank from reaching the boiling point. This was achieved by incorporating a specific percentage of paraffin, a PCM, with a melting point of 85 °C. The size of the hot storage tank containing both water and a specified proportion of paraffin, in addition to the solar collector area, was optimized to maximize the tank temperature. These parameters were entered into the energy balance model as input data to ensure the effective operation of the absorption system under optimal conditions. A comprehensive system simulation was conducted by deriving and simplifying the heat balance equations for the hybrid hot storage tank, the solar collector, and the absorption system. The simulation aimed to identify the optimal wax ratio of 5% to 20% to maximize system performance. The optimal paraffin ratio was found to be 10% of the tank volume, which enabled an additional 4 hours of operation and extended the system’s uptime to its maximum potential.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 5 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Tikrit
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Aadel A. R. AlkumaitUniversity of Tikrit2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Improve the thermal performance of the combined water-paraffin hot storage tank in the absorption cooling cycle</dc:title>
	<dc:creator>Zaidan, Maki Haj</dc:creator>
	<dc:creator>Ibrahim, Thamir Khalil</dc:creator>
	<dc:creator>Dheyab, Hussam S.</dc:creator>
	<dc:subject xml:lang="en-US">absorption cooling system; concentric parabolic collectors; paraffin PCM; phase change material; storage tank</dc:subject>
	<dc:description xml:lang="en-US">This research investigates the thermal performance of storage materials in a hot tank designed to extend the operation time of a 1.5-ton water ammonia absorption cooling system. Thermal energy is supplied by concentric parabolic solar collectors, which heat the absorption cycle generator during periods of sufficient solar radiation. When the water temperature exceeds the system’s operating threshold, the additional heat accumulates in the hot tank. It is later used to drive the generator during periods of low solar availability, such as in the afternoon or after sunset. The system is designed to provide air conditioning for a room; its load was calculated hourly. The suitable size of the storage tank and the corresponding collector area were determined based on simulations of the absorption system to achieve an optimal coefficient of performance (COP). The collector area was increased after the addition of paraffin phase change material (PCM) to enhance system performance, and a temperature control strategy was implemented to prevent the water in the hot storage tank from reaching the boiling point. This was achieved by incorporating a specific percentage of paraffin, a PCM, with a melting point of 85 °C. The size of the hot storage tank containing both water and a specified proportion of paraffin, in addition to the solar collector area, was optimized to maximize the tank temperature. These parameters were entered into the energy balance model as input data to ensure the effective operation of the absorption system under optimal conditions. A comprehensive system simulation was conducted by deriving and simplifying the heat balance equations for the hybrid hot storage tank, the solar collector, and the absorption system. The simulation aimed to identify the optimal wax ratio of 5% to 20% to maximize system performance. The optimal paraffin ratio was found to be 10% of the tank volume, which enabled an additional 4 hours of operation and extended the system’s uptime to its maximum potential.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21940</dc:identifier>
	<dc:identifier>10.11591/ijape.v14.i4.pp1011-1022</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 4: December 2025; 1011-1022</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v14.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21940/13382</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Maki Haj Zaidan, Thamir Khalil Ibrahim, Hussam S. Dheyab</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>