Abstrak

Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 120 tautan kepenulisan bersama · 31 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Malikussaleh University
  • Universiti Malaysia Perlis
  • University of Mataram
  • Universitas Tidar
  • Lampung University
  • Udayana University
  • Universitas Islam Negeri Ar-Raniry
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Rizky AlmunadiansyahMalikussaleh University8
Agung Budi MuljonoUniversity of Mataram5
I Made GinarsaUniversity of Mataram5
Muhammad DaudMalikussaleh University5
Kartika KartikaMalikussaleh University4
Widyana Verawaty SiregarMalikussaleh University4
Fahrian RoidMalikussaleh University4
Sultan SultanUniversity of Mataram3
Rahmati RahmatiAfiliasi tidak diketahui3
Osea ZebuaLampung University2
Mulyadi Abdul WahidAfiliasi tidak diketahui2
Zara YunizarMalikussaleh University2
Asran AsranMalikussaleh University2
Nura UsrinaMalikussaleh University2
Nuryawan NuryawanMalikussaleh University2
Farhan AkbarMalikussaleh University2
Selamat MelialaMalikussaleh University2
Rosdiana RosdianaMalikussaleh University2
Raihan PutriMalikussaleh University2
Agus DharmaUdayana University1
N. S. B. JamiliUniversiti Malaysia Perlis1
Mohd Rafi AdzmanUniversiti Malaysia Perlis1
Siti Rafidah Abdul RahimUniversiti Malaysia Perlis1
Samila Mat ZaliUniversiti Malaysia Perlis1
Hafizuddin HanafiUniversiti Malaysia Perlis1
Sabar NababanUniversity of Mataram1
Suwito Eko PramonoAfiliasi tidak diketahui1
Kustiono KustionoAfiliasi tidak diketahui1
Darmiah DarmiahUniversitas Islam Negeri Ar-Raniry1
Aida OktarizaAfiliasi tidak diketahui1
Reza SafitriUniversity of Brawijaya1
Sri MutiaAfiliasi tidak diketahui1
Yulia WulandariAfiliasi tidak diketahui1
Fauzi Sahlan Rizki SinagaMalikussaleh University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Assessing transformer health through analysis of dissolved gases in cooling oil</dc:title>
	<dc:creator>Nisworo, Sapto</dc:creator>
	<dc:creator>Hasibuan, Arnawan</dc:creator>
	<dc:creator>Isa, Muzamir</dc:creator>
	<dc:creator>Nrartha, I Made Ari</dc:creator>
	<dc:creator>Jannah, Misbahul</dc:creator>
	<dc:creator>Muhammad, Muhammad</dc:creator>
	<dc:subject xml:lang="en-US">dissolved gas analysis; insulation system failure; rogers ratio; transformer fault; transformer oil</dc:subject>
	<dc:description xml:lang="en-US">Gases can form within the insulation system for various reasons while a transformer is in operation. If these gases are not promptly and properly managed, they can negatively impact the transformer's performance. Using the dissolved gas analysis (DGA) method to identify and assess the type and quantity of dissolved gases in transformer oil can uncover potential issues within the transformer. This information is crucial for guiding preventive maintenance and necessary repairs. Dissolved gas analysis testing was conducted by extracting transformer oil samples to identify signs of disturbances in the transformer based on the dissolved gas content. This research was conducted at the Paiton plant operations and maintenance services division. The condition of transformers was assessed by analyzing dissolved gases using the Rogers ratio method. Results indicate that the transformer at Paiton 9 is in good condition but overheating has occurred and requires treatment. Conversely, the transformers at Paiton 1 and 2 are in poor condition, showing signs of electrical faults and excessive heat. Despite several attempts to add inhibitors and conduct frequent testing, the transformers remained in poor condition, necessitating their replacement or repair.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21138</dc:identifier>
	<dc:identifier>10.11591/ijape.v13.i4.pp1014-1020</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 13, No 4: December 2024; 1014-1020</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v13.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21138/13262</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Arnawan Hasibuan, Sapto Nisworo, Muzamir Isa</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>