Akses terbuka
Jurnal
SINTA 1
Contribution to the comparison of conventional concentric magnetic gear and double stage concentric magnetic gear for high power offshore wind applications
International Journal of Applied Power Engineering (IJAPE) · Vol. 13 No. 1 (2024) · hlm. 30–44
ISSN 2722-2624, 2252-8792
Terbit 2024-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
Nowadays, the replacement of mechanical technologies by magnetic technologies has several advantages. Therefore, in this paper, we compare in an indirect drive chain the conventional concentric magnetic gear (CCMG) and the double-stage concentric magnetic gear (DSCMG) used as a speed multiplier for a high-power offshore wind turbine. This comparison is performed for the same gear ratio and the same torque at the input of both magnetic gears to obtain the same torque values at the output of each gear. The goal is to determine which one has the smaller amount of magnet and the higher volumetric torque density. After the calculation of the gear ratio, a first choice of geometrical parameters is adopted. Several simulations carried out by the finite element method (FEM) allowed to obtain the desired torques and to fix the final geometrical parameters of each magnetic gear. The results obtained show that the DSCMG has both the smallest magnet volume and the highest volumetric torque density compared to the CCMG.
Jaringan kolaborasi para penulis
10 penulis ·
31 tautan kepenulisan bersama
· 24 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Université d'Abomey-Calavi National University of Sciences, Technologies, Engineering and Mathematics Université Nationale d'Agriculture Université de Maradi University of Douala
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Contribution to the comparison of conventional concentric magnetic gear and double stage concentric magnetic gear for high power offshore wind applications</dc:title>
<dc:creator>Philippe, d’Almeida Renaud</dc:creator>
<dc:creator>Gilles, Agbokpanzo Richard</dc:creator>
<dc:creator>Macaire, Agbomahena Bienvenu</dc:creator>
<dc:subject xml:lang="en-US">concentric magnetic gear; double-stage magnetic gear; gear ratio indirect drive chain; torque density</dc:subject>
<dc:description xml:lang="en-US">Nowadays, the replacement of mechanical technologies by magnetic technologies has several advantages. Therefore, in this paper, we compare in an indirect drive chain the conventional concentric magnetic gear (CCMG) and the double-stage concentric magnetic gear (DSCMG) used as a speed multiplier for a high-power offshore wind turbine. This comparison is performed for the same gear ratio and the same torque at the input of both magnetic gears to obtain the same torque values at the output of each gear. The goal is to determine which one has the smaller amount of magnet and the higher volumetric torque density. After the calculation of the gear ratio, a first choice of geometrical parameters is adopted. Several simulations carried out by the finite element method (FEM) allowed to obtain the desired torques and to fix the final geometrical parameters of each magnetic gear. The results obtained show that the DSCMG has both the smallest magnet volume and the highest volumetric torque density compared to the CCMG.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2024-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20685</dc:identifier>
<dc:identifier>10.11591/ijape.v13.i1.pp30-44</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 13, No 1: March 2024; 30-44</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v13.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20685/13148</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Renaud d'ALMEIDA</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Philippe, d. R., Gilles, A. R., & Macaire, A. B. (2024). Contribution to the comparison of conventional concentric magnetic gear and double stage concentric magnetic gear for high power offshore wind applications. International Journal of Applied Power Engineering (IJAPE), 13(1), 30–44. https://doi.org/10.11591/ijape.v13.i1.pp30-44
Salin
IEEE
d. R. Philippe, A. R. Gilles, and A. B. Macaire, “Contribution to the comparison of conventional concentric magnetic gear and double stage concentric magnetic gear for high power offshore wind applications,” International Journal of Applied Power Engineering (IJAPE), vol. 13, no. 1, pp. 30–44, 2024, doi: 10.11591/ijape.v13.i1.pp30-44.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.