Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Analysis of switched impedance source/quasi-impedance source DC-DC converters for photovoltaic system

International Journal of Applied Power Engineering (IJAPE) · Vol. 11 No. 1 (2022) · hlm. 14–24

DOI
10.11591/ijape.v11.i1.pp14-24
ISSN
2722-2624, 2252-8792
Terbit
2022-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper proposes the switched impedance source converter (SZSC) or switched quasi impedance source DC-DC converter (S-qZSC) based photovoltaic (PV) grid-connected systems. To increase the voltage from low level to high level, all PV grid-connected systems need step-up DC-DC converters. This step-up factor can be increased by connecting the terminals of a traditional quasi impedance source DC-DC converter with an additional diode and a switch. In this proposed converter, the capacitor not only serves as a filter. It is, however, bound in series to the charging loops of the inductors. On the one hand, saturated inductors can trigger instability, which can be avoided. When used for dc-ac conversion, however, the modulation index of the backend H-bridge can be set to a wider range. As compared to existing Z-source-based systems, a shorter duty period results in a higher boost factor.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 17 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Osmania University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sangem Ravi KumarOsmania University3
Saieni AkhileshOsmania University2
P. SatishkumarOsmania University1
P. Satish KumarAfiliasi tidak diketahui1
N. SusheelaAfiliasi tidak diketahui1
P. Satish KumarOsmania University1
Mohd Abdul NazeemuddinOsmania University1
Laxminarayana YalakantiOsmania University1
Savitri SwathiOsmania University1
Bhaskaruni Suresh KumarOsmania University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analysis of switched impedance source/quasi-impedance source DC-DC converters for photovoltaic system</dc:title>
	<dc:creator>Sreenu, Sapavath</dc:creator>
	<dc:creator>Upendar, Jalla</dc:creator>
	<dc:creator>Sirisha, Bogimi</dc:creator>
	<dc:subject xml:lang="en-US">DC-DC converter; impedance-source converter; PV array; quasi impedance source converter</dc:subject>
	<dc:description xml:lang="en-US">This paper proposes the switched impedance source converter (SZSC) or switched quasi impedance source DC-DC converter (S-qZSC) based photovoltaic (PV) grid-connected systems. To increase the voltage from low level to high level, all PV grid-connected systems need step-up DC-DC converters. This step-up factor can be increased by connecting the terminals of a traditional quasi impedance source DC-DC converter with an additional diode and a switch. In this proposed converter, the capacitor not only serves as a filter. It is, however, bound in series to the charging loops of the inductors. On the one hand, saturated inductors can trigger instability, which can be avoided. When used for dc-ac conversion, however, the modulation index of the backend H-bridge can be set to a wider range. As compared to existing Z-source-based systems, a shorter duty period results in a higher boost factor.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20461</dc:identifier>
	<dc:identifier>10.11591/ijape.v11.i1.pp14-24</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 11, No 1: March 2022; 14-24</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v11.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20461/12987</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 sirisha bogimi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>