Abstrak

The wide deployment of grid-connected renewable energy system has piqued immense attention recently, in response to rising electricity consumption, diminishing fossil fuel reserves in addition to the need for reducing carbon emissions. Among the available sources of renewable energy, photovoltaic (PV) power generation is the most promising technology with enormous potential and easy access. This paper presents an optimum control technique for grid connected PV systems. The improved single ended primary inductor converter (SEPIC) controls and regulates PV output power to the optimum voltage level. The working of the improved SEPIC is controlled by a proportional-integral (PI) controller optimized by meta-heuristic technique of lion swarm optimization (LSO). The constant output from the converter is then supplied to the power grid through a single-phase voltage source inverter (1πœ™ VSI). The effectiveness of the proposed control strategy is ascertained using hardware validation with DSPIC3050FPGA controller and MATLAB simulation generating a reduced total harmonic distortion (THD) of 3.9% and 2.9%, respectively. Furthermore, the proposed system generates an enhanced voltage gain of 1:10 and an efficiency of 96%.

Kata kunci

Jaringan kolaborasi para penulis

25 penulis Β· 74 tautan kepenulisan bersama Β· 25 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Saveetha University
  • AMET University
  • Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology
  • INTI International University
  • Symbiosis International University
  • Rajalakshmi Engineering College
  • Easwari Engineering College
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama Β· lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Pushpa SreenivasanAMET University4
Malathy BatumalayINTI International University3
Deepa SomasundaramAfiliasi tidak diketahui2
Helaria MariaAfiliasi tidak diketahui1
Sangeetha MuruganAfiliasi tidak diketahui1
Sudipta BanerjeeSymbiosis International University1
Jayashree KathirvelRajalakshmi Engineering College1
Marlin SagayarajAfiliasi tidak diketahui1
Vijay Anand JagadeesanAfiliasi tidak diketahui1
Shanthi NatarajanAfiliasi tidak diketahui1
Amudhapriya SivakumarAfiliasi tidak diketahui1
I. Arul Doss AdaikalamEaswari Engineering College1
G. PrakashSri Sairam Engineering College1
N. RajavinuAfiliasi tidak diketahui1
P. KavithaAfiliasi tidak diketahui1
V. DevarajAfiliasi tidak diketahui1
G. JegadeeswariSaveetha University1
G. RohiniSaveetha University1
D. BalakumarSaveetha University1
S. MarisargunamSaveetha University1
B. KirubaduraiVel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Lion swarm optimization for grid connected PV system with improved SEPIC</dc:title>
	<dc:creator>Annapandi, P.</dc:creator>
	<dc:creator>Lakshmi, D.</dc:creator>
	<dc:creator>Santhoshi, B. Kavya</dc:creator>
	<dc:creator>Annapoorani, P.</dc:creator>
	<dc:subject xml:lang="en-US">1πœ™ VSI; improved SEPIC; LSO; PI controller; PV system</dc:subject>
	<dc:description xml:lang="en-US">The wide deployment of grid-connected renewable energy system has piqued immense attention recently, in response to rising electricity consumption, diminishing fossil fuel reserves in addition to the need for reducing carbon emissions. Among the available sources of renewable energy, photovoltaic (PV) power generation is the most promising technology with enormous potential and easy access. This paper presents an optimum control technique for grid connected PV systems. The improved single ended primary inductor converter (SEPIC) controls and regulates PV output power to the optimum voltage level. The working of the improved SEPIC is controlled by a proportional-integral (PI) controller optimized by meta-heuristic technique of lion swarm optimization (LSO). The constant output from the converter is then supplied to the power grid through a single-phase voltage source inverter (1πœ™ VSI). The effectiveness of the proposed control strategy is ascertained using hardware validation with DSPIC3050FPGA controller and MATLAB simulation generating a reduced total harmonic distortion (THD) of 3.9% and 2.9%, respectively. Furthermore, the proposed system generates an enhanced voltage gain of 1:10 and an efficiency of 96%.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20853</dc:identifier>
	<dc:identifier>10.11591/ijape.v13.i3.pp603-615</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 13, No 3: September 2024; 603-615</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v13.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20853/13212</dc:relation>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>