Abstrak

The integrity of the insulation in oil-filled power transformers, shunt reactors, and high voltage bushings can be affected when copper dissolves in the insulating oil and then deposits onto the paper insulation. The presence of dissolved copper in the oil increases dielectric losses, while copper deposition significantly improves the conductivity of the paper insulation. Various factors, including temperature, oxygen, sulfur groups, passivators, and ageing time, have been found to contribute to the acceleration of corrosion activity in transformer insulating oils. Unfortunately, there is a lack of extensive research focused on systematically analysing and measuring the impact of corrosion-related factors on the dissolution of copper in transformer insulating oils and the deposition of copper onto solid insulation surfaces (Kraft paper). Therefore, this study aims to thoroughly examine the effects of corrosion factors on copper and sulfur deposition on Kraft paper insulation when it is submerged in transformer mineral oil (TMO). Using a two-level (2k) factorial design, we investigated three crucial factors: i) oil temperature, ii) elemental sulfur concentration, and iii) ageing time. It is worth mentioning that the results obtained from the two-level factorial design indicate that the surface resistivity is primarily affected by the temperature of the oil. This factor alone explains a significant 38.68% of the observed variation. In order to improve predictability, a regression model was created to estimate the surface resistivity of TMO-impregnated paper insulation. This model takes into account factors such as oil temperature, elemental sulfur concentration, and ageing time.

Kata kunci

Jaringan kolaborasi para penulis

34 penulis · 105 tautan kepenulisan bersama · 31 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • Tun Hussein Onn University of Malaysia
  • University of Technology Malaysia
  • Universiti Sains Malaysia
  • Universiti Malaysia Kelantan
  • Universiti Tenaga Nasional
  • Universitas Ahmad Dahlan
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Hidayat ZainuddinUniversiti Teknikal Malaysia Melaka9
Norazhar B. Abu BakarUniversiti Teknikal Malaysia Melaka6
Mohd Safwan MohamadUniversiti Teknikal Malaysia Melaka4
Nur Izyan Husnina ZulkefliUniversiti Teknikal Malaysia Melaka4
Nor Hidayah RahimUniversiti Teknikal Malaysia Melaka4
Mohd Zamri Che WanikUniversiti Malaysia Kelantan3
Muhammad Syahrani JohalUniversiti Teknikal Malaysia Melaka3
Muhammad Asyraf ZainalAfiliasi tidak diketahui3
Nor Asiah MuhamadUniversiti Sains Malaysia2
Zulkarnain Ahmad NoordenUniversity of Technology Malaysia2
Muhammad Ilman Hakimi Chua AbdullahUniversiti Teknikal Malaysia Melaka2
Nur Amirah OthmanUniversiti Teknikal Malaysia Melaka1
Aminuddin AmanUniversiti Teknikal Malaysia Melaka1
Sharin Abd GhaniAfiliasi tidak diketahui1
Ezreen Farina ShairUniversiti Teknikal Malaysia Melaka1
Nur Zawani SaharuddinUniversiti Teknikal Malaysia Melaka1
Amar Saufi NasirUniversiti Teknikal Malaysia Melaka1
Izham Zainal AbidinUniversiti Tenaga Nasional1
Rahisham Abd RahmanTun Hussein Onn University of Malaysia1
Mohd Fairouz Mohd YousofTun Hussein Onn University of Malaysia1
Nurul Farahwahida Md YasidTun Hussein Onn University of Malaysia1
Tole SutiknoUniversitas Ahmad Dahlan1
Auzani JidinUniversiti Teknikal Malaysia Melaka1
Nor Azizah Mohd YusoffUniversiti Teknikal Malaysia Melaka1
Kasrul Abdul KarimUniversiti Teknikal Malaysia Melaka1
M. S. KamarudinTun Hussein Onn University of Malaysia1
Ayuamira ZahariUniversiti Teknikal Malaysia Melaka1
Nur Farhani AmboUniversiti Teknikal Malaysia Melaka1
Jamaludin Mohd WariAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Investigating the effects of corrosion parameters on the surface resistivity of transformer’s insulating paper using a two-level factorial design</dc:title>
	<dc:creator>Azlan, Nur Farhana Mohd</dc:creator>
	<dc:creator>Ghani, Sharin Ab</dc:creator>
	<dc:creator>Khiar, Mohd Shahril Ahmad</dc:creator>
	<dc:creator>Chairul, Imran Sutan</dc:creator>
	<dc:creator>Din, Mohamad Nazri Mohamad</dc:creator>
	<dc:subject xml:lang="en-US">design of experiment; experiment parameters; factorial design; kraft paper; mineral insulating oil; surface resistivity; transformer</dc:subject>
	<dc:description xml:lang="en-US">The integrity of the insulation in oil-filled power transformers, shunt reactors, and high voltage bushings can be affected when copper dissolves in the insulating oil and then deposits onto the paper insulation. The presence of dissolved copper in the oil increases dielectric losses, while copper deposition significantly improves the conductivity of the paper insulation. Various factors, including temperature, oxygen, sulfur groups, passivators, and ageing time, have been found to contribute to the acceleration of corrosion activity in transformer insulating oils. Unfortunately, there is a lack of extensive research focused on systematically analysing and measuring the impact of corrosion-related factors on the dissolution of copper in transformer insulating oils and the deposition of copper onto solid insulation surfaces (Kraft paper). Therefore, this study aims to thoroughly examine the effects of corrosion factors on copper and sulfur deposition on Kraft paper insulation when it is submerged in transformer mineral oil (TMO). Using a two-level (2k) factorial design, we investigated three crucial factors: i) oil temperature, ii) elemental sulfur concentration, and iii) ageing time. It is worth mentioning that the results obtained from the two-level factorial design indicate that the surface resistivity is primarily affected by the temperature of the oil. This factor alone explains a significant 38.68% of the observed variation. In order to improve predictability, a regression model was created to estimate the surface resistivity of TMO-impregnated paper insulation. This model takes into account factors such as oil temperature, elemental sulfur concentration, and ageing time.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Ministry of Higher Education Malaysia</dc:contributor>
	<dc:contributor xml:lang="en-US">Universiti Teknikal Malaysia Melaka</dc:contributor>
	<dc:date>2024-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20856</dc:identifier>
	<dc:identifier>10.11591/ijape.v13.i2.pp335-342</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 13, No 2: June 2024; 335-342</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v13.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20856/13193</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Sharin Ab Ghani</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>