Frequency response-based optimization of PID controllers for enhanced fluid control system performance

International Journal of Applied Power Engineering (IJAPE) · Vol. 14 No. 4 (2025) · hlm. 1058–1070

DOI
10.11591/ijape.v14.i4.pp1058-1070
ISSN
2722-2624, 2252-8792
Terbit
2025-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Temperature and viscosity variations are known to affect the performance of proportional-integral-derivative (PID) controllers in fluid systems. However, there exist gaps in research relative to the thermal effects on the performance of PID based fluid systems. PID controllers are also utilized for fluid control to maintain stability and improve performance. This study aims to explore the influence of temperature and viscosity variations through frequency response analysis for the first time in this regard. Utilizing a controlled experimental setup, gain and phase values were measured across different temperature points. Bode and Nyquist plots were generated to observe system behavior, stability, and response to changes in temperature and fluid viscosity. The results show a clear inverse relationship between temperature and gain, with a notable phase lag increase as temperature rises. At 25 °C, the gain was measured at 15.83 dB with a phase of -52.63°, which gradually reduced to a gain of 13 dB and a phase of -61.53° at 80 °C. The Nyquist analysis revealed stable operation within this temperature range, but the shift in response indicates increased system vulnerability as viscosity decreases with rising temperature. The derived linear equations effectively model the gain-phase relationship, with an R² of 0.9985, suggesting a highly accurate fit. Overall, the study concludes that temperature-induced viscosity changes significantly impact PID-controlled fluid systems, emphasizing the need for adaptive control strategies in fluctuating environments.

Kata kunci

Jaringan kolaborasi para penulis

36 penulis · 164 tautan kepenulisan bersama · 72 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Medan Area University
  • Universitas Sumatera Utara
  • Universitas Maritim Raja Ali Haji
  • Andalas University
  • National Chung Hsing University
  • Süleyman Demirel Üniversitesi
  • Indonesian Institute of Sciences
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Habib SatriaMedan Area University5
Muhammad Fadlan SiregarMedan Area University4
Syafii SyafiiAndalas University3
Moranain MungkinMedan Area University3
Indri DayanaMedan Area University3
Dina MaizanaMedan Area University2
Indri DayanaMedan Area University2
Siti Utari RahayuNational Chung Hsing University2
Saharman GeaUniversitas Sumatera Utara2
Averroes Fazlur Rahman PiliangUniversitas Sumatera Utara2
Diana Alemin BarusUniversitas Sumatera Utara2
Bimbi Aditya WanatirtaAfiliasi tidak diketahui1
Rahmat Kholis HarahapSüleyman Demirel Üniversitesi1
Septia ReflyAfiliasi tidak diketahui1
Basyaruddin Ismail HarahapUniversitas Maritim Raja Ali Haji1
Seri Dermayu SAfiliasi tidak diketahui1
A S RatnaUniversitas Sumatera Utara1
Tua Raja SUniversitas Sumatera Utara1
S PerdameanIndonesian Institute of Sciences1
Muhammad IrwantoUniversiti Malaysia Perlis1
M. IrwantoUniversitas Prima Indonesia1
Hermansyah HermansyahMedan Area University1
Martha RiannaUniversitas Sumatera Utara1
Juliaster MarbunUniversity of HKBP Nommensen1
Nidya ChitraningrumNational Research and Innovation Agency1
Tino HermantoMedan Area University1
Yopan Rahmad AldoriMedan Area University1
Mega Puspita SariMedan Area University1
Syofyan Anwar SyahputraRiau University1
Junaidi JunaidiAfiliasi tidak diketahui1
Ade Irma SagalaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Frequency response-based optimization of PID controllers for enhanced fluid control system performance</dc:title>
	<dc:creator>Frianto, Herri Trisna</dc:creator>
	<dc:creator>Humaidi, Syahrul</dc:creator>
	<dc:creator>Tarigan, Kerista</dc:creator>
	<dc:creator>Ramdan, Dadan</dc:creator>
	<dc:creator>Bonardo, Doli</dc:creator>
	<dc:subject xml:lang="en-US">fluid dynamics; PID control; stability analysis; temperature variation; viscosity</dc:subject>
	<dc:description xml:lang="en-US">Temperature and viscosity variations are known to affect the performance of proportional-integral-derivative (PID) controllers in fluid systems. However, there exist gaps in research relative to the thermal effects on the performance of PID based fluid systems. PID controllers are also utilized for fluid control to maintain stability and improve performance. This study aims to explore the influence of temperature and viscosity variations through frequency response analysis for the first time in this regard. Utilizing a controlled experimental setup, gain and phase values were measured across different temperature points. Bode and Nyquist plots were generated to observe system behavior, stability, and response to changes in temperature and fluid viscosity. The results show a clear inverse relationship between temperature and gain, with a notable phase lag increase as temperature rises. At 25 °C, the gain was measured at 15.83 dB with a phase of -52.63°, which gradually reduced to a gain of 13 dB and a phase of -61.53° at 80 °C. The Nyquist analysis revealed stable operation within this temperature range, but the shift in response indicates increased system vulnerability as viscosity decreases with rising temperature. The derived linear equations effectively model the gain-phase relationship, with an R² of 0.9985, suggesting a highly accurate fit. Overall, the study concludes that temperature-induced viscosity changes significantly impact PID-controlled fluid systems, emphasizing the need for adaptive control strategies in fluctuating environments.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21649</dc:identifier>
	<dc:identifier>10.11591/ijape.v14.i4.pp1058-1070</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 4: December 2025; 1058-1070</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v14.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21649/13386</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Herri Trisna Frianto, Syahrul Humaidi, Kerista Tarigan, Dadan Ramdan, Doli Bonardo</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>