Abstrak

The Squirrel Cage Induction Motor (SCIM) with advanced power electronic inverters presents the greater advantages on cost and energy efficiency as compared with other industrial solutions for varying speed applications. In recent, the inverter fed induction motors are being popular in the industries. These inverter fed-motors are recently gathering great recognition for multimegawatt industrial drive applications. In this present paper, a dynamic simulation model of PWM inverter fed SCIM with direct torque control jointly has been presented and analyzed in the recent MATLAB/Simulink environment. From the proposed simulation model, the transient behavior of SCIM has been analysed for healthy as well as for stator inter-turn fault condition. The dynamic simulation of induction motor is one of the key steps in the validation of design process of the electric motor and drive system. It is extremely needed for eliminating probable faults beforehand due to inadvertent design mistakes and changes during operation. The simulated model gives encouraging results with reduced harmonics [1]. By using the model, the successful detection of stator inter-turn fault of the SCIM is carried out in the transient condition. Therefore, early stator fault detection is possible and may avoid the motor to reach in the catastrophic conditions. Therefore, may save millions of dollars for industries.

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Madan Mohan Malaviya University of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ranitesh GuptaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Stator Inter-turn Fault Detection in Inverter Fed Induction Motor Drives</dc:title>
	<dc:creator>Siddiqui, Khadim Moin</dc:creator>
	<dc:creator>Sahay, Kuldeep</dc:creator>
	<dc:creator>Giri, V. K.</dc:creator>
	<dc:description xml:lang="en-US">The Squirrel Cage Induction Motor (SCIM) with advanced power electronic inverters presents the greater advantages on cost and energy efficiency as compared with other industrial solutions for varying speed applications. In recent, the inverter fed induction motors are being popular in the industries. These inverter fed-motors are recently gathering great recognition for multimegawatt industrial drive applications. In this present paper, a dynamic simulation model of PWM inverter fed SCIM with direct torque control jointly has been presented and analyzed in the recent MATLAB/Simulink environment. From the proposed simulation model, the transient behavior of SCIM has been analysed for healthy as well as for stator inter-turn fault condition. The dynamic simulation of induction motor is one of the key steps in the validation of design process of the electric motor and drive system. It is extremely needed for eliminating probable faults beforehand due to inadvertent design mistakes and changes during operation. The simulated model gives encouraging results with reduced harmonics [1]. By using the model, the successful detection of stator inter-turn fault of the SCIM is carried out in the transient condition. Therefore, early stator fault detection is possible and may avoid the motor to reach in the catastrophic conditions. Therefore, may save millions of dollars for industries.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-08-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/8144</dc:identifier>
	<dc:identifier>10.11591/ijape.v6.i2.pp89-102</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 6, No 2: August 2017; 89-102</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v6.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/8144/12253</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Institute of Advanced Engineering and Science</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>