Abstrak

This article proposes a nine-level switched capacitor inverter (NLSCI) with a minimum number of switches. In recent years, switching capacitor (SC) multilevel inverters (MLIs) have become one of the most common inverter topologies. These proposed nine level switched capacitor inverter (NLSCI) do not deserve any external control unit for capacitor control. Since, the charging and discharging of the capacitors are controlled by the on and off states of switches. Furthermore, by employing fewer switches and DC voltage sources, the suggested design produces a greater amount of resultant voltage. Additionally, pulse width modulation (PWM) is recommended as a method to enhance output quality and power level quality. The switched-capacitor two-output multilevel inverter (SCMLI) structure's viability and effectiveness have been demonstrated using MATLAB simulation.

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 12 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohan Babu University
  • Arunai Engineering College
  • SASTRA University
  • Annamalai University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
N. M. G. KumarAfiliasi tidak diketahui1
Natarajan PrabaharanSASTRA University1
M. ArumugamArunai Engineering College1
B. ShanthiAnnamalai University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Nine level switched capacitor inverter with level shifted pulse width modulation approach</dc:title>
	<dc:creator>Arun, Vijayakumar</dc:creator>
	<dc:creator>Prasad, Thunga Nageswara</dc:creator>
	<dc:creator>Prabhu, Sundaramoorthy</dc:creator>
	<dc:creator>Ashokkumar, Nagarajan</dc:creator>
	<dc:subject xml:lang="en-US">inverter; MLI; NLSCI; POD; SPWM; THD</dc:subject>
	<dc:description xml:lang="en-US">This article proposes a nine-level switched capacitor inverter (NLSCI) with a minimum number of switches. In recent years, switching capacitor (SC) multilevel inverters (MLIs) have become one of the most common inverter topologies. These proposed nine level switched capacitor inverter (NLSCI) do not deserve any external control unit for capacitor control. Since, the charging and discharging of the capacitors are controlled by the on and off states of switches. Furthermore, by employing fewer switches and DC voltage sources, the suggested design produces a greater amount of resultant voltage. Additionally, pulse width modulation (PWM) is recommended as a method to enhance output quality and power level quality. The switched-capacitor two-output multilevel inverter (SCMLI) structure's viability and effectiveness have been demonstrated using MATLAB simulation.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20791</dc:identifier>
	<dc:identifier>10.11591/ijape.v13.i1.pp130-137</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 13, No 1: March 2024; 130-137</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v13.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20791/13141</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Vijayakumar Arun</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>