Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Hourly scheduling of thermal units utilizing an innovative hybrid approach

International Journal of Applied Power Engineering (IJAPE) · Vol. 15 No. 2 (2026) · hlm. 600–609

DOI
10.11591/ijape.v15.i2.pp600-609
ISSN
2722-2624, 2252-8792
Terbit
2026-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The producing unit must be turned on at a time that meets the power system network's needs. It also determines the order of unit shutdowns based on cost. Unit commitment includes computation and turning units on and off. Committed units are planned to join the power system network. The combinatorial character of unit commitment makes it a crucial research issue and optimization job in contemporary power system. In order to effectively use the available resources and equalize the load demand on an hourly basis, unit commitment might be used. In order to solve an optimization issue involving unit commitment, this work introduces a new hybrid approach that combines a whale optimization algorithm (WOA) with a self-organizing migration algorithm (SOMA). An important part of any migration loop is the WOA technique, which is used to evaluate the optimum strength population from the populations that are created stochastically. The suggested hybrid approach is evaluated using two test systems. Before moving on to the IEEE 39 bus system, a four-unit system is implemented. The efficiency of the suggested hybrid WAOSOMA is addressed by comparing the generated simulation results with approaches found in the literature.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 27 tautan kepenulisan bersama · 11 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jawaharlal Nehru Technological University Anantapur
  • Vel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology
  • Osmania University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Pradyumna Kumar DhalVel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology3
Shaik Hussain ValiJawaharlal Nehru Technological University Anantapur3
S. Vinoth John PrakashVel Tech Rangarajan Dr. Sagunthala R&D Institute of Science and Technology3

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Hourly scheduling of thermal units utilizing an innovative hybrid approach</dc:title>
	<dc:creator>Rafi, Vempalle</dc:creator>
	<dc:creator>Vali, Shaik Hussain</dc:creator>
	<dc:creator>Krishna, Sadhu Radha</dc:creator>
	<dc:creator>Suryavalli, Uppuluri</dc:creator>
	<dc:creator>Rajesh, M.</dc:creator>
	<dc:creator>Prateepkumar, Sayapogu</dc:creator>
	<dc:subject xml:lang="en-US">hourly basis; migration loop; self-organizing migrating; unit commitment; whale optimization</dc:subject>
	<dc:description xml:lang="en-US">The producing unit must be turned on at a time that meets the power system network's needs. It also determines the order of unit shutdowns based on cost. Unit commitment includes computation and turning units on and off. Committed units are planned to join the power system network. The combinatorial character of unit commitment makes it a crucial research issue and optimization job in contemporary power system. In order to effectively use the available resources and equalize the load demand on an hourly basis, unit commitment might be used. In order to solve an optimization issue involving unit commitment, this work introduces a new hybrid approach that combines a whale optimization algorithm (WOA) with a self-organizing migration algorithm (SOMA). An important part of any migration loop is the WOA technique, which is used to evaluate the optimum strength population from the populations that are created stochastically. The suggested hybrid approach is evaluated using two test systems. Before moving on to the IEEE 39 bus system, a four-unit system is implemented. The efficiency of the suggested hybrid WAOSOMA is addressed by comparing the generated simulation results with approaches found in the literature.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21873</dc:identifier>
	<dc:identifier>10.11591/ijape.v15.i2.pp600-609</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 15, No 2: June 2026; 600-609</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v15.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21873/13446</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Vempalle Rafi, Shaik Hussain Vali, Sadhu Radha Krishna, Uppuluri Suryavalli, M. Rajesh, Sayapogu Prateepkumar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>