Akses terbuka
Jurnal
SINTA 1
ANFIS and PI based performance analysis of three phase three wire distribution system for THD reduction
International Journal of Applied Power Engineering (IJAPE) · Vol. 14 No. 3 (2025) · hlm. 752–760
ISSN 2722-2624, 2252-8792
Terbit 2025-09-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
Due to the rising usage of nonlinear loads and power electronic devices in businesses, one of the key power system concerns today is inadequacy of power quality (PQ). This article presents compensation of current harmonics in distribution system in source side by using adaptive neuro fuzzy inferences system (ANFIS) controller. DSTATCOM optimized proportional integral (PI) controller and ANFIS regulator are utilized for DC link voltage regulation. The ANFIS controller showed better performance compared to PI controller during compensating harmonics time. This paper compared two control schemes results PI and ANFIS. Three-phase three-wire inverter is used for DSTATCOM circuit. In the results compared DC capacitor voltage and total harmonic distortion (THD) values of source current. The THD with PI controller is 7.92% while by using ANFIS controller it is reduced to 2.76%. The concert of proposed method is analyzed with MATLAB/Simulink software.
Jaringan kolaborasi para penulis
18 penulis ·
42 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Karunya University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">ANFIS and PI based performance analysis of three phase three wire distribution system for THD reduction</dc:title>
<dc:creator>Sreejyothi, Khammampati R.</dc:creator>
<dc:creator>Jayakumar, J.</dc:creator>
<dc:creator>Kumar, P. Venkatesh</dc:creator>
<dc:subject xml:lang="en-US">ANFIS controller; harmonics; PI controller; power quality; total harmonic distortion</dc:subject>
<dc:description xml:lang="en-US">Due to the rising usage of nonlinear loads and power electronic devices in businesses, one of the key power system concerns today is inadequacy of power quality (PQ). This article presents compensation of current harmonics in distribution system in source side by using adaptive neuro fuzzy inferences system (ANFIS) controller. DSTATCOM optimized proportional integral (PI) controller and ANFIS regulator are utilized for DC link voltage regulation. The ANFIS controller showed better performance compared to PI controller during compensating harmonics time. This paper compared two control schemes results PI and ANFIS. Three-phase three-wire inverter is used for DSTATCOM circuit. In the results compared DC capacitor voltage and total harmonic distortion (THD) values of source current. The THD with PI controller is 7.92% while by using ANFIS controller it is reduced to 2.76%. The concert of proposed method is analyzed with MATLAB/Simulink software.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2025-09-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21137</dc:identifier>
<dc:identifier>10.11591/ijape.v14.i3.pp752-760</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 3: September 2025; 752-760</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v14.i3</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21137/13356</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2025 Khammampati R. Sreejyothi, J. Jayakumar, P. Venkatesh Kumar</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Sreejyothi, K. R., Jayakumar, J., & Kumar, P. V. (2025). ANFIS and PI based performance analysis of three phase three wire distribution system for THD reduction. International Journal of Applied Power Engineering (IJAPE), 14(3), 752–760. https://doi.org/10.11591/ijape.v14.i3.pp752-760
Salin
IEEE
K. R. Sreejyothi, J. Jayakumar, and P. V. Kumar, “ANFIS and PI based performance analysis of three phase three wire distribution system for THD reduction,” International Journal of Applied Power Engineering (IJAPE), vol. 14, no. 3, pp. 752–760, 2025, doi: 10.11591/ijape.v14.i3.pp752-760.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.