Abstrak

Due to the rising usage of nonlinear loads and power electronic devices in businesses, one of the key power system concerns today is inadequacy of power quality (PQ). This article presents compensation of current harmonics in distribution system in source side by using adaptive neuro fuzzy inferences system (ANFIS) controller. DSTATCOM optimized proportional integral (PI) controller and ANFIS regulator are utilized for DC link voltage regulation. The ANFIS controller showed better performance compared to PI controller during compensating harmonics time. This paper compared two control schemes results PI and ANFIS. Three-phase three-wire inverter is used for DSTATCOM circuit. In the results compared DC capacitor voltage and total harmonic distortion (THD) values of source current. The THD with PI controller is 7.92% while by using ANFIS controller it is reduced to 2.76%. The concert of proposed method is analyzed with MATLAB/Simulink software.

Kata kunci

Jaringan kolaborasi para penulis

18 penulis · 42 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Karunya University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Anitha Angeline AKarunya University2
Kalagotla ChenchireddyKarunya University2
Abbagoni SrujanaAfiliasi tidak diketahui1
Golluri RamcharanAfiliasi tidak diketahui1
Dharavath NagarajuAfiliasi tidak diketahui1
Dhunnapothula RaghuAfiliasi tidak diketahui1
Banoth Nithish KumarAfiliasi tidak diketahui1
Podishetti GaneshAfiliasi tidak diketahui1
G. KiranAfiliasi tidak diketahui1
Chilukuri ShivaAfiliasi tidak diketahui1
Lazarus Godson AsirvathamKarunya University1
Vidhya KuruvillaKarunya University1
Francisxavier Thomas JoshKarunya University1
Jeyaraj Jency JosephAfiliasi tidak diketahui1
Karunakar thadkapallyKarunya University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">ANFIS and PI based performance analysis of three phase three wire distribution system for THD reduction</dc:title>
	<dc:creator>Sreejyothi, Khammampati R.</dc:creator>
	<dc:creator>Jayakumar, J.</dc:creator>
	<dc:creator>Kumar, P. Venkatesh</dc:creator>
	<dc:subject xml:lang="en-US">ANFIS controller; harmonics; PI controller; power quality; total harmonic distortion</dc:subject>
	<dc:description xml:lang="en-US">Due to the rising usage of nonlinear loads and power electronic devices in businesses, one of the key power system concerns today is inadequacy of power quality (PQ). This article presents compensation of current harmonics in distribution system in source side by using adaptive neuro fuzzy inferences system (ANFIS) controller. DSTATCOM optimized proportional integral (PI) controller and ANFIS regulator are utilized for DC link voltage regulation. The ANFIS controller showed better performance compared to PI controller during compensating harmonics time. This paper compared two control schemes results PI and ANFIS. Three-phase three-wire inverter is used for DSTATCOM circuit. In the results compared DC capacitor voltage and total harmonic distortion (THD) values of source current. The THD with PI controller is 7.92% while by using ANFIS controller it is reduced to 2.76%. The concert of proposed method is analyzed with MATLAB/Simulink software.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2025-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21137</dc:identifier>
	<dc:identifier>10.11591/ijape.v14.i3.pp752-760</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 3: September 2025; 752-760</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v14.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21137/13356</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Khammampati R. Sreejyothi, J. Jayakumar, P. Venkatesh Kumar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>