Abstrak
Distribution systems or networks are inherently unbalanced. As a result, single-phase power flow methods are generally no longer valid for such systems. Therefore, to obtain accurate results, unbalanced systems should be analyzed using three-phase power flow methods, which are far more complicated than the single-phase methods. Moreover, at present, the penetration of distributed generation (DG) in the distribution network has significantly increased. DG integration will increase the complication of the power flow analysis as it changes the network's basic configuration from passive to active system. This computational burden will significantly be higher if the power flow calculation has to be conducted several times (for example, in feeder reconfigurations or service restorations). This paper investigates the utilization of the trust-region method in obtaining the solution to the three-phase power flow problem of an active distribution network (i.e., distribution network embedded with DG). Trust-region computation algorithm is robust and powerful since the optimization technique is employed in finding new solutions in the iteration process. Results obtained from three representative unbalanced distribution networks (i.e., 10-node, 19-node, and 25-node networks) verify the validity of the proposed method. The effects of DG installation on distribution network steady-state performances are also investigated in the present paper.
Jaringan kolaborasi para penulis
5 penulis ·
5 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Three-phase power flow solution of active distribution network using trust-region method</dc:title>
<dc:creator>Gianto, Rudy</dc:creator>
<dc:creator>Arsyad, M. Iqbal</dc:creator>
<dc:creator>Rajagukguk, Managam</dc:creator>
<dc:subject xml:lang="en-US">active distribution network; distributed generation; power flow; trust-region method; unbalanced distribution system</dc:subject>
<dc:description xml:lang="en-US">Distribution systems or networks are inherently unbalanced. As a result, single-phase power flow methods are generally no longer valid for such systems. Therefore, to obtain accurate results, unbalanced systems should be analyzed using three-phase power flow methods, which are far more complicated than the single-phase methods. Moreover, at present, the penetration of distributed generation (DG) in the distribution network has significantly increased. DG integration will increase the complication of the power flow analysis as it changes the network's basic configuration from passive to active system. This computational burden will significantly be higher if the power flow calculation has to be conducted several times (for example, in feeder reconfigurations or service restorations). This paper investigates the utilization of the trust-region method in obtaining the solution to the three-phase power flow problem of an active distribution network (i.e., distribution network embedded with DG). Trust-region computation algorithm is robust and powerful since the optimization technique is employed in finding new solutions in the iteration process. Results obtained from three representative unbalanced distribution networks (i.e., 10-node, 19-node, and 25-node networks) verify the validity of the proposed method. The effects of DG installation on distribution network steady-state performances are also investigated in the present paper.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2025-12-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21602</dc:identifier>
<dc:identifier>10.11591/ijape.v14.i4.pp923-933</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 14, No 4: December 2025; 923-933</dc:source>
<dc:source>2722-2624</dc:source>
<dc:source>2252-8792</dc:source>
<dc:source>10.11591/ijape.v14.i4</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21602/13374</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2025 Rudy Gianto, M. Iqbal Arsyad, Managam Rajagukguk</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Gianto, R., Arsyad, M. I., & Rajagukguk, M. (2025). Three-phase power flow solution of active distribution network using trust-region method. International Journal of Applied Power Engineering (IJAPE), 14(4), 923–933. https://doi.org/10.11591/ijape.v14.i4.pp923-933
Salin
IEEE
R. Gianto, M. I. Arsyad, and M. Rajagukguk, “Three-phase power flow solution of active distribution network using trust-region method,” International Journal of Applied Power Engineering (IJAPE), vol. 14, no. 4, pp. 923–933, 2025, doi: 10.11591/ijape.v14.i4.pp923-933.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.