Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Experimental analysis of DI-ZSI based DSTATCOM

International Journal of Applied Power Engineering (IJAPE) · Vol. 12 No. 3 (2023) · hlm. 341–348

DOI
10.11591/ijape.v12.i3.pp341-348
ISSN
2722-2624, 2252-8792
Terbit
2023-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This article presents the dual operation of distributed energy resources (DER) integrated impedance source inverter (DI-ZSI). The distribution grid, DER and variable nonlinear load are operating on two modes. In mode-1, power generated by the DER is zero or less then the load requirement and the inverter act as a voltage source inverter (VSI) for shunt compensation only. But, in mode-2, power generated by the DER greater than the load requirement and operates as a DI-ZSI based distributed static compensator (DSTATCOM). In this scenario, it not only acts as a shunt compensator but also inject active power to the distribution grid. An accurately tuned proportional integral with adaptive least mean square (ALMS) controller is used to generate the switching signals of inverter switches. The DI-ZSI performs stable operation in the distribution grid over a variable non-linear loading. A field programmable gate array (FPGA) SPARTAN-6 controller is used to develop the proposed system. Experimental results from DI-ZSI and VSI under variable loading highlighted the superiority of the DI-ZSI as per guidelines imposed by IEEE-2030-7-2017.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 29 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Odisha University of Technology and Research
  • Lovely Professional University
  • G H Raisoni University
  • GMR Institute of Technology
  • Vallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Suresh Kumar SudabattulaLovely Professional University2
S. K. MishraG H Raisoni University2
Vasupalli ManojGMR Institute of Technology1
Malleti SreedharVallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology1
Rebba SasidharAfiliasi tidak diketahui1
Dasyam Chandra MouliAfiliasi tidak diketahui1
Ramana PillaGMR Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Experimental analysis of DI-ZSI based DSTATCOM</dc:title>
	<dc:creator>Sabat, Jogeswara</dc:creator>
	<dc:creator>Mangaraj, Mrutyunjaya</dc:creator>
	<dc:creator>Barisal, Ajit Kumar</dc:creator>
	<dc:creator>Kundala, Praveen Kumar Yadav</dc:creator>
	<dc:creator>Thakur, Rohan Vijay</dc:creator>
	<dc:subject xml:lang="en-US">adaptive least mean square; distributed energy resources; DI-ZSI; DSTATCOM; voltage source inverter</dc:subject>
	<dc:description xml:lang="en-US">This article presents the dual operation of distributed energy resources (DER) integrated impedance source inverter (DI-ZSI). The distribution grid, DER and variable nonlinear load are operating on two modes. In mode-1, power generated by the DER is zero or less then the load requirement and the inverter act as a voltage source inverter (VSI) for shunt compensation only. But, in mode-2, power generated by the DER greater than the load requirement and operates as a DI-ZSI based distributed static compensator (DSTATCOM). In this scenario, it not only acts as a shunt compensator but also inject active power to the distribution grid. An accurately tuned proportional integral with adaptive least mean square (ALMS) controller is used to generate the switching signals of inverter switches. The DI-ZSI performs stable operation in the distribution grid over a variable non-linear loading. A field programmable gate array (FPGA) SPARTAN-6 controller is used to develop the proposed system. Experimental results from DI-ZSI and VSI under variable loading highlighted the superiority of the DI-ZSI as per guidelines imposed by IEEE-2030-7-2017.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2023-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20559</dc:identifier>
	<dc:identifier>10.11591/ijape.v12.i3.pp341-348</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 12, No 3: September 2023; 341-348</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v12.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20559/13086</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Jogeswara Sabat</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>