Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Self tuning of output scaling factor for type-2 interval fuzzy controllers

International Journal of Applied Power Engineering (IJAPE) · Vol. 15 No. 2 (2026) · hlm. 480–491

DOI
10.11591/ijape.v15.i2.pp480-491
ISSN
2722-2624, 2252-8792
Terbit
2026-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In this study presents a self-tuning type-2 fuzzy logic controller framework, which operates on the principle of continuously adjusting the controller structure by modifying the controller gain (scaling factor) as a function of the error and its rate of change, in order to achieve optimal control performance. The proposed structure is both simple and robust, with real-time gain adaptation facilitated by two type-2 fuzzy systems; the first one containing the rules of control task for speed regulation, and the second one containing the rules for the adaptation of the scaling factor. Both systems have the same inputs error and its variation. This work specifically focuses on tuning the output scaling factor, which is considered equivalent to the controller gain. The effectiveness of the proposed approach is evaluated through its application to the control of an induction machine, a system known for its complexity and strong nonlinearity. Simulation results demonstrate that the fuzzy controller significantly enhances performance, even under challenging operating conditions such as low-speed regimes.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 31 tautan kepenulisan bersama · 14 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Batna 2
  • University of Eloued
  • Centre Universitaire Morsli Abdellah de Tipaza
  • University of Biskra
  • Ahlia University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Souheib RemhaAfiliasi tidak diketahui1
Khaled MiloudiUniversity of Eloued1
Ala Eddine DjokhrabUniversity of Eloued1
Mosbah LaouamerUniversity of Eloued1
Yacine AounUniversity of Eloued1
Madina HamianeAhlia University1
Mohamed Tahar MakhloufiUniversity of Batna 21
Azzeddine YahiaUniversity of Batna 21
Nadjiba TerkiUniversity of Biskra1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Self tuning of output scaling factor for type-2 interval fuzzy controllers</dc:title>
	<dc:creator>Ghanai, Mouna</dc:creator>
	<dc:creator>Chafaa, Kheireddine</dc:creator>
	<dc:creator>Medjghou, Ali</dc:creator>
	<dc:creator>Bounouara, Nadia</dc:creator>
	<dc:subject xml:lang="en-US">adaptive scaling factor; gain self tuning; induction motors; type-2 fuzzy controllers; type-2 fuzzy logic</dc:subject>
	<dc:description xml:lang="en-US">In this study presents a self-tuning type-2 fuzzy logic controller framework, which operates on the principle of continuously adjusting the controller structure by modifying the controller gain (scaling factor) as a function of the error and its rate of change, in order to achieve optimal control performance. The proposed structure is both simple and robust, with real-time gain adaptation facilitated by two type-2 fuzzy systems; the first one containing the rules of control task for speed regulation, and the second one containing the rules for the adaptation of the scaling factor. Both systems have the same inputs error and its variation. This work specifically focuses on tuning the output scaling factor, which is considered equivalent to the controller gain. The effectiveness of the proposed approach is evaluated through its application to the control of an induction machine, a system known for its complexity and strong nonlinearity. Simulation results demonstrate that the fuzzy controller significantly enhances performance, even under challenging operating conditions such as low-speed regimes.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/21810</dc:identifier>
	<dc:identifier>10.11591/ijape.v15.i2.pp480-491</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 15, No 2: June 2026; 480-491</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v15.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/21810/13434</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Mouna Ghanai, Kheireddine Chafaa, Ali Medjghou, Nadia Bounouara</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>