Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Cases of PD-CFPID selector for frequency adjustment of integrated power grid

International Journal of Applied Power Engineering (IJAPE) · Vol. 13 No. 2 (2024) · hlm. 428–433

DOI
10.11591/ijape.v13.i2.pp428-433
ISSN
2722-2624, 2252-8792
Terbit
2024-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

In current article an improved salp swarm algorithm (SSA) has been suggested. Likewise, the adjustable scaling-component is locked in to manage salp’s situation in time of the hunt system to limit arbitrary development salps. The upgraded salp swarm method combines random objection-based learning, multiple management, and simulated hardening in swarm brilliant-based metaheuristic salp swarm method, which rises the exploration and exploitation of the primary salp swarm method. To exhibit viability of the improved SSA, a bunch of multichannel test capabilities are locked in. A partially decentralized combined fuzzy proportional integral derivative (PD-CFPID) regulator is planned for integrated grid. A partially decentralized robust control plan is introduced to deal with a class of multi-inputs multi outputs (MIMO) non-square, linear framework different systems. Partially decentralized command is a control composition that lies between a completely decentralized structure and a wholly centralized one, and has the primacy of achieving comparable performance as an entirely centralized regulator but with simpler shape. The proposed flexible partially decoupled command scheme works in a straightforward and systematic way. Simulations show that the proposed partially decentralized control performs well for the nonlinear system, nearly equivalent to the multivariable control, and they achieve better performance indexes. Simulation outcomes appear that the stated method is simple and can reach better performance. The results of the PD-CFPID regulator are compare among CFPID and PID as many circumstances of the presented control outlook.

Kata kunci

Jaringan kolaborasi para penulis

25 penulis · 56 tautan kepenulisan bersama · 19 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Siksha O Anusandhan University
  • C.V. Raman Global University
  • GITAM University
  • Government College of Engineering, Keonjhar
  • KIIT University
  • Odisha University of Agriculture and Technology
  • Vellore Institute of Technology University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nalinikanta MohantyAfiliasi tidak diketahui2
Subhransu Sekhar DashGovernment College of Engineering, Keonjhar2
Ajoya Kumar PradhanGITAM University2
Smitta Ranjan DuttaAfiliasi tidak diketahui1
Akshaya Kumar PatraAfiliasi tidak diketahui1
Alok Kumar MishraSiksha O Anusandhan University1
Ramachandra AgrawalAfiliasi tidak diketahui1
Dillip Kumar SubudhiAfiliasi tidak diketahui1
Lalit Mohan SatapathyAfiliasi tidak diketahui1
Sarita SamalKIIT University1
Prasanta Kumar BarikAfiliasi tidak diketahui1
Mahendra Kumar MohantyOdisha University of Agriculture and Technology1
Sarat Kumar SahooVellore Institute of Technology University1
Priyanka SenC.V. Raman Global University1
Vandana JhaR.V. College of Engineering1
Manoj Kumar DebnathSiksha O Anusandhan University1
Sabita TripathySiksha O Anusandhan University1
Nalin Kant MohantySri Venkateswara College of Engineering Tirupati1
D. AmudhavalliAnna University, Chennai1
M AnupriyaSSN Educational and Charitable Trust1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijape.iaescore.com/index.php/IJAPE/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Cases of PD-CFPID selector for frequency adjustment of integrated power grid</dc:title>
	<dc:creator>Sahoo, Ananta Kumar</dc:creator>
	<dc:creator>Nayak, Smrutiranjan</dc:creator>
	<dc:creator>Sahoo, Ashwin Kumar</dc:creator>
	<dc:creator>Dash, Subhransu Sekhar</dc:creator>
	<dc:creator>Kar, Sanjeeb Kumar</dc:creator>
	<dc:subject xml:lang="en-US">combined fuzzy PID; distributed power system; enhanced SSA; frequency control; partially decentralized</dc:subject>
	<dc:description xml:lang="en-US">In current article an improved salp swarm algorithm (SSA) has been suggested. Likewise, the adjustable scaling-component is locked in to manage salp’s situation in time of the hunt system to limit arbitrary development salps. The upgraded salp swarm method combines random objection-based learning, multiple management, and simulated hardening in swarm brilliant-based metaheuristic salp swarm method, which rises the exploration and exploitation of the primary salp swarm method. To exhibit viability of the improved SSA, a bunch of multichannel test capabilities are locked in. A partially decentralized combined fuzzy proportional integral derivative (PD-CFPID) regulator is planned for integrated grid. A partially decentralized robust control plan is introduced to deal with a class of multi-inputs multi outputs (MIMO) non-square, linear framework different systems. Partially decentralized command is a control composition that lies between a completely decentralized structure and a wholly centralized one, and has the primacy of achieving comparable performance as an entirely centralized regulator but with simpler shape. The proposed flexible partially decoupled command scheme works in a straightforward and systematic way. Simulations show that the proposed partially decentralized control performs well for the nonlinear system, nearly equivalent to the multivariable control, and they achieve better performance indexes. Simulation outcomes appear that the stated method is simple and can reach better performance. The results of the PD-CFPID regulator are compare among CFPID and PID as many circumstances of the presented control outlook.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijape.iaescore.com/index.php/IJAPE/article/view/20838</dc:identifier>
	<dc:identifier>10.11591/ijape.v13.i2.pp428-433</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Applied Power Engineering (IJAPE); Vol 13, No 2: June 2024; 428-433</dc:source>
	<dc:source>2722-2624</dc:source>
	<dc:source>2252-8792</dc:source>
	<dc:source>10.11591/ijape.v13.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijape.iaescore.com/index.php/IJAPE/article/view/20838/13199</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 Smrutiranjan Nayak</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>