Abstrak

The transmission of electric power has to take place in the most efficient way in addition to providing flexibility in the process. Flexible A.C. Transmission System (FACTS) promotes the use of static controllers to enhance the controllability and increase the power transfer capability. Providing reactive shunt compensation with shunt-connected capacitors and reactors is a well-established technique to get a better voltage profile in a power system. Shunt Capacitors are inexpensive but lack dynamic capabilities, thus some form of dynamically controlled reactive power compensation becomes essential. In this paper, three phase Distribution Static Var Compensator (D-SVC) has been developed and studied under different conditions. Open loop mode and closed loop mode of operation of D-SVC is simulated and studied. The work presented here is very much useful for distribution system, for effective reactive power management and better Voltage control.

Jaringan kolaborasi para penulis

12 penulis · 21 tautan kepenulisan bersama · 11 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • C.V. Raman Global University
  • Siksha O Anusandhan University
  • Vellore Institute of Technology University
  • R.V. College of Engineering
  • Anna University, Chennai
  • Sri Venkateswara College of Engineering Tirupati
  • SSN Educational and Charitable Trust
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
M AnupriyaSSN Educational and Charitable Trust2
Sanjeeb Kumar KarSiksha O Anusandhan University1
Smrutiranjan NayakSiksha O Anusandhan University1
Ananta Kumar SahooC.V. Raman Global University1
Subhransu Sekhar DashAfiliasi tidak diketahui1
Priyanka SenC.V. Raman Global University1
Vandana JhaR.V. College of Engineering1
Nalin Kant MohantySri Venkateswara College of Engineering Tirupati1
D. AmudhavalliAnna University, Chennai1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Modeling and Simulation of Three Phase D-SVC for Load Compensation</dc:title>
	<dc:creator>Sahoo, Ashwin Kumar</dc:creator>
	<dc:creator>Sahoo, Sarat Kumar</dc:creator>
	<dc:creator>Mohanty, Nalinikanta</dc:creator>
	<dc:description xml:lang="en-US">The transmission of electric power has to take place in the most efficient way in addition to providing flexibility in the process. Flexible A.C. Transmission System (FACTS) promotes the use of static controllers to enhance the controllability and increase the power transfer capability. Providing reactive shunt compensation with shunt-connected capacitors and reactors is a well-established technique to get a better voltage profile in a power system. Shunt Capacitors are inexpensive but lack dynamic capabilities, thus some form of dynamically controlled reactive power compensation becomes essential.  In this paper, three phase Distribution Static Var Compensator (D-SVC) has been developed and studied under different conditions. Open loop mode and closed loop mode of operation of D-SVC is simulated and studied. The work presented here is very much useful for distribution system, for effective reactive power management and better Voltage control.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6154</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i1.pp262-271</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 1: March 2017; 262-271</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6154/6003</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Ashwin Kumar Sahoo, Sarat Kumar Sahoo, Nalinikanta Mohanty</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>