Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Enhanced Three-Phase Inverter Faults Detection And Diagnosis Approach - Design And Experimental Evaluation

International Journal of Power Electronics and Drive Systems · Vol. 9 No. 2 (2018) · hlm. 559–570

DOI
10.11591/ijpeds.v9.i2.pp559-570
ISSN
2722-256X, 2088-8694
Terbit
2018-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Efficiency, reliability, high power quality and continuous operation are important aspects in electric vehicle attraction system. Therefore, quick fault detection, isolation and enhanced fault-tolerant control for open-switches faults in inverter driving systems become more and more required in this filed. However, fault detection and localization algorithms have been known to have many performance limitations due to speed variations such as wrong decision making of fault occurrence. Those weaknesses are investigated and solved in this paper using currents magnitudes fault indices, current direct component fault indices and a decision system. A simulation model and experimental setup are utilized to validate the proposed concept. Many simulation and experimental results are carried out to show the effectiveness of the proposed fault detection approach.

Jaringan kolaborasi para penulis

19 penulis · 49 tautan kepenulisan bersama · 18 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mohamed I University
  • Université Ibn Zohr
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Institut of Research in Solar Energy and New Energies
  • Aix-Marseille Université
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Smail ZouggarMohamed I University6
Sara ZerdaniAfiliasi tidak diketahui2
Mustapha KourchiUniversité Ibn Zohr1
Mohamed AjaamoumUniversité Ibn Zohr1
Samia JenkalUniversité Ibn Zohr1
Driss YousfiUniversiti Malaysia Pahang Al-Sultan Abdullah1
Ahmed BenlarabiInstitut of Research in Solar Energy and New Energies1
Mhand OubellaUniversité Ibn Zohr1
Mhamed FannakhMohamed I University1
Hassan ZahbouneMohamed I University1
Mohammed EL FahssiMohamed I University1
Taoufik OuchbelMohamed I University1
Badreddine LahfaouiAfiliasi tidak diketahui1
M Djouadi SeddikAfiliasi tidak diketahui1
Mohammed MokhtariMohamed I University1
N.K. M’SirdiAix-Marseille Université1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 29 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Enhanced Three-Phase Inverter Faults Detection And Diagnosis Approach - Design And Experimental Evaluation</dc:title>
	<dc:creator>Fadil, Hicham</dc:creator>
	<dc:creator>Elhafyani, Mohamed Larbi</dc:creator>
	<dc:creator>Zouggar, Smail</dc:creator>
	<dc:description xml:lang="en-US">Efficiency, reliability, high power quality and continuous operation are important aspects in electric vehicle attraction system. Therefore, quick fault detection, isolation and enhanced fault-tolerant control for open-switches faults in inverter driving systems become more and more required in this filed. However, fault detection and localization algorithms have been known to have many performance limitations due to speed variations such as wrong decision making of fault occurrence. Those weaknesses are investigated and solved in this paper using currents magnitudes fault indices, current direct component fault indices and a decision system. A simulation model and experimental setup are utilized to validate the proposed concept. Many simulation and experimental results are carried out to show the effectiveness of the proposed fault detection approach.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2018-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/10142</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v9.i2.pp559-570</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 9, No 2: June 2018; 559-570</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v9.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/10142/11182</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Hicham Fadil, Mohamed Larbi Elhafyani, Smail Zouggar</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>