Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Mitigation of current harmonics in multi-drive system

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 1 (2022) · hlm. 113–121

DOI
10.11591/ijpeds.v13.i1.pp113-121
ISSN
2722-256X, 2088-8694
Terbit
2022-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Most of the fully automated industries are mainly depending on the single and multi-drive system based on their requirements. In this paper, to investigate the power quality problems in a distributed multi drive system connected to the common uncontrolled rectifier is considered. Uncontrolled rectifier is mainly used as a front-end converter to feed direct current (DC) supply to the same rating of two voltage source inverters with induction motors as a multi-drive system. To analyse the effectiveness of the system the two drive systems are operated in different time period. Then, both are operated simultaneously to monitor the power quality issues, due to the front-end converter present in the system. In both the cases the harmonics in source current is not within the limits of IEEE recommended practices. Therefore, to reduce the harmonic content present in the current at source, a shunt active power filter is implemented. The effect of two drive systems operated at the same time is analysed first. Then, active filter is injected in between the source and the multi-drive system in parallel to improve the power quality of the grid system. The individual and multi-drive drive systems are analysed with the simulation results.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 136 tautan kepenulisan bersama · 18 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • SRM Institute of Science and Technology
  • SRM University
  • Dhanalakshmi Srinivasan University
  • American International University-Bangladesh
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Krishnasamy VijayakumarSRM Institute of Science and Technology13
K. SelvakumarSRM Institute of Science and Technology11
D. SelvabharathiSRM Institute of Science and Technology6
D. KarthikeyanSRM Institute of Science and Technology5
S. VidyasagarSRM Institute of Science and Technology5
Subbulakshmy RamamurthiSRM Institute of Science and Technology5
Kalyanasundaram VakesanSRM Institute of Science and Technology4
Vidyasagar SugavanamSRM Institute of Science and Technology4
V. KalyanasundaramSRM Institute of Science and Technology3
K. SaravananSRM Institute of Science and Technology2
Selvakumar KuppusamySRM Institute of Science and Technology2
Ramkumar RavindranDhanalakshmi Srinivasan University2
Ravindran RamkumarDhanalakshmi Srinivasan University2
Priyanka DasSRM Institute of Science and Technology1
Gaurav Kumar SinghSRM Institute of Science and Technology1
Sourav SinhaAmerican International University-Bangladesh1
Arnab NagSRM Institute of Science and Technology1
A. VeluAfiliasi tidak diketahui1
V. VenkatachalamSRM Institute of Science and Technology1
R. Mano NarayananSRM Institute of Science and Technology1
D. SaravanakumarSRM Institute of Science and Technology1
Arul Rayappan StalinSRM University1
P. GopiSRM University1
P. PonselvinSRM University1
S. George FernandezSRM Institute of Science and Technology1
V. KalyanasundhramSRM Institute of Science and Technology1
Th. Ankit SinghSRM Institute of Science and Technology1
Anamika RanjanSRM Institute of Science and Technology1
Jatin P SinghSRM Institute of Science and Technology1
C. S. BoopathiSRM Institute of Science and Technology1
R. SridharSRM Institute of Science and Technology1
Rohit SahasrabuddheSRM Institute of Science and Technology1
Mathur Kartik HiteshkumarSRM Institute of Science and Technology1
Jay Anil PuranikSRM Institute of Science and Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Mitigation of current harmonics in multi-drive system</dc:title>
	<dc:creator>Thentral, Thamizh</dc:creator>
	<dc:creator>Rathakrishnan, Ramya</dc:creator>
	<dc:creator>Anbalagan, Velu</dc:creator>
	<dc:creator>Dhandapani, Karthikeyan</dc:creator>
	<dc:creator>Sengamalai, Usha</dc:creator>
	<dc:creator>Ramasamy, Palanisamy</dc:creator>
	<dc:subject xml:lang="en-US">adjustable speed drive; diode rectifier; direct torque control; harmonics; multi-drive system; shunt active power filter</dc:subject>
	<dc:description xml:lang="en-US">Most of the fully automated industries are mainly depending on the single and multi-drive system based on their requirements. In this paper, to investigate the power quality problems in a distributed multi drive system connected to the common uncontrolled rectifier is considered. Uncontrolled rectifier is mainly used as a front-end converter to feed direct current (DC) supply to the same rating of two voltage source inverters with induction motors as a multi-drive system. To analyse the effectiveness of the system the two drive systems are operated in different time period. Then, both are operated simultaneously to monitor the power quality issues, due to the front-end converter present in the system. In both the cases the harmonics in source current is not within the limits of IEEE recommended practices. Therefore, to reduce the harmonic content present in the current at source, a shunt active power filter is implemented. The effect of two drive systems operated at the same time is analysed first. Then, active filter is injected in between the source and the multi-drive system in parallel to improve the power quality of the grid system. The individual and multi-drive drive systems are analysed with the simulation results.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2022-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21669</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i1.pp113-121</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 1: March 2022; 113-121</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21669/13724</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Thamizh Thentral, Ramya Rathakrishnan, Velu Anbalagan, Karthikeyan Dhandapani, Usha Sengamalai, Palanisamy Ramasamy</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>