Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A Comparative Study of Z-Source Inverter Fed Three-Phase IM Drive with CSI and VSI fed IM

International Journal of Power Electronics and Drive Systems · Vol. 3 No. 3 (2013) · hlm. 259–270

ISSN
2722-256X, 2088-8694
Terbit
2013-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper cite comparative performance characteristics of Z-Source inverter fed IM drives with mostly used VSI & CSI fed IM drives. ZSI has both voltages buck and boost capabilities as they allow inverters to be operated in the shoot through state. It employs an exclusive Z-Source network (LC component) to dc-link the main inverter circuit to the power source (rectifier). By controlling the shoot-through duty cycle, the inverter system using IGBTS reduces the line harmonics, improves power factor, increases reliability and extends output voltage range. It has reduced harmonics, low switching stress power and low common mode noise as compared to VSI. Simulation results are given to compare the behavior of conventional and proposed topology and also demonstrate the new features of the improved topology i.e ZSI fed IM. Simulation results of ZSI fed IM gives different performance characteristics as compared to VSI & CSI fed IM drives such as its stator & rotor current characteristics, speed characteristics, torque characteristics which put a gloss on the VSI fed IM performance.DOI: http://dx.doi.org/10.11591/ijpeds.v3i3.3869

Jaringan kolaborasi para penulis

9 penulis · 13 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National Institute of Technology Hamirpur
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Priyesh Kumar PandeyNational Institute of Technology Hamirpur1
R. K. JarialNational Institute of Technology Hamirpur1
Deepak KumarNational Institute of Technology Hamirpur1
Khushbu ThakurNational Institute of Technology Hamirpur1
Mohd. Arif KhanAfiliasi tidak diketahui1
Sk Moin AhmadAfiliasi tidak diketahui1
Atif IqbalAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A Comparative Study of Z-Source Inverter Fed Three-Phase IM Drive with CSI and VSI fed IM</dc:title>
	<dc:creator>Kumar, Deepak</dc:creator>
	<dc:creator>Husain, Zakir</dc:creator>
	<dc:description xml:lang="en-US">This paper cite comparative performance characteristics of Z-Source inverter fed IM drives with mostly used VSI &amp;amp; CSI fed IM drives. ZSI has both voltages buck and boost capabilities as they allow inverters to be operated in the shoot through state. It employs an exclusive Z-Source network (LC component) to dc-link the main inverter circuit to the power source (rectifier). By controlling the shoot-through duty cycle, the inverter system using IGBTS reduces the line harmonics, improves power factor, increases reliability and extends output voltage range. It has reduced harmonics, low switching stress power and low common mode noise as compared to VSI. Simulation results are given to compare the behavior of conventional and proposed topology and also demonstrate the new features of the improved topology i.e ZSI fed IM. Simulation results of  ZSI fed IM gives different performance characteristics as compared to VSI &amp;amp; CSI fed IM drives such as its stator &amp;amp; rotor current characteristics, speed characteristics , torque characteristics which put a gloss on the VSI fed IM performance.DOI: http://dx.doi.org/10.11591/ijpeds.v3i3.3869</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2013-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4951</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 3, No 3: September 2013; 259-270</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v3.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/4951/5069</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2013 Deepak Kumar, Zakir Husain</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>