Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Investigation of efficiency and safety in wireless capacitive power transfer through a single-layer tissue phantom

International Journal of Power Electronics and Drive Systems · Vol. 17 No. 1 (2026) · hlm. 502–517

DOI
10.11591/ijpeds.v17.i1.pp502-517
ISSN
2722-256X, 2088-8694
Terbit
2026-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Wireless power transfer (WPT) is a promising solution for implantable biomedical devices, offering an alternative to traditional implanted batteries and percutaneous connections, which are limited by short lifespans and high infection risks. Existing capacitive power transfer (CPT) systems for biomedical implants often utilize media such as animal meat or liquids to validate power transfer across the human body, but these materials exhibit inconsistent and inaccurate dielectric properties. To address this limitation, this study proposes a CPT system designed to operate with a single-layer tissue phantom that closely mimics the dielectric characteristics of human tissue. The system is integrated with a class-E LCCL resonant topology to enhance power transfer efficiency. In addition to evaluating performance, this work also investigates safety aspects in terms of electric field emission and specific absorption rate (SAR). Simulations using MATLAB Simulink and ANSYS HFSS reveal that at a 1 mm tissue gap, the electric field reaches 298.09 V/m and the SAR is 1.14 W/kg, which are both within established safety limits (614 V/m and 2 W/kg per 10 g of tissue). Furthermore, a 5 W, 1 MHz system operating across a 2 mm tissue gap demonstrates power transfer efficiencies of 40.61% for skin tissue and 20.53% for muscle tissue. These results validate the system’s safety and efficiency for powering deeply implanted biomedical devices.

Kata kunci

Jaringan kolaborasi para penulis

39 penulis · 139 tautan kepenulisan bersama · 36 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknikal Malaysia Melaka
  • Universiti Teknologi MARA
  • Christian-Albrechts-Universität zu Kiel
  • Universiti Malaysia Terengganu
  • University of Auckland
  • Universiti Malaysia Perlis
  • University of Technology Malaysia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Siti Huzaimah HusinUniversiti Teknikal Malaysia Melaka9
Md Rabiul AwalUniversiti Malaysia Terengganu9
Khairul Kamarudin HasanUniversiti Teknologi MARA9
A. A. M. IsaUniversiti Teknikal Malaysia Melaka6
F. K. A. RahmanAfiliasi tidak diketahui5
Ahmad Husni Mohd ShapriUniversiti Malaysia Perlis5
Yusmarnita YusofUniversiti Teknikal Malaysia Melaka3
Norezmi JamalUniversiti Teknikal Malaysia Melaka3
Thoriq ZaidUniversiti Teknikal Malaysia Melaka3
Muslimah MeorUniversiti Teknikal Malaysia Melaka3
Nor Diyana Md SinUniversiti Teknologi MARA3
R. A. RaniUniversiti Teknikal Malaysia Melaka3
F. K. Abdul RahmanAfiliasi tidak diketahui3
Ahmed Al-HattamiAfiliasi tidak diketahui3
Youssef Abdel AzizAfiliasi tidak diketahui3
Mohd Shakir Md SaatUniversiti Teknikal Malaysia Melaka2
Sing Kiong NguangUniversity of Auckland2
N. X. YinUniversiti Teknikal Malaysia Melaka2
Masmaria Abdul MajidUniversiti Teknologi MARA2
Mohd Sufian RamliUniversiti Teknologi MARA2
Mohd Haizal JamaluddinUniversity of Technology Malaysia2
M. S. M. IsaUniversiti Teknikal Malaysia Melaka2
N NabilaUniversiti Teknikal Malaysia Melaka2
Amat Amir BasariUniversiti Teknikal Malaysia Melaka2
Zaki MustapaUniversiti Teknikal Malaysia Melaka1
Imran HindustanUniversiti Teknikal Malaysia Melaka1
A. M. DarsonoUniversiti Teknikal Malaysia Melaka1
O. Z. GuatAfiliasi tidak diketahui1
F.K. Abdul RahmanAfiliasi tidak diketahui1
Muhammad Zaki MustapaUniversiti Teknikal Malaysia Melaka1
Zamre Abdul GhaniUniversiti Teknikal Malaysia Melaka1
SK NguangAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Investigation of efficiency and safety in wireless capacitive power transfer through a single-layer tissue phantom</dc:title>
	<dc:creator>Yusop, Yusmarnita</dc:creator>
	<dc:creator>Ngu, Amy Sarah</dc:creator>
	<dc:creator>Qi, Cheok Yan</dc:creator>
	<dc:creator>Asan, N. B.</dc:creator>
	<dc:creator>Husin, Huzaimah</dc:creator>
	<dc:creator>Saat, Shakir</dc:creator>
	<dc:creator>Hoeher, Peter Adam</dc:creator>
	<dc:subject xml:lang="en-US">capacitive power transfer; class-e inverter; electric field emission; LCCL impedance matching; specific absorption rate</dc:subject>
	<dc:description xml:lang="en-US">Wireless power transfer (WPT) is a promising solution for implantable biomedical devices, offering an alternative to traditional implanted batteries and percutaneous connections, which are limited by short lifespans and high infection risks. Existing capacitive power transfer (CPT) systems for biomedical implants often utilize media such as animal meat or liquids to validate power transfer across the human body, but these materials exhibit inconsistent and inaccurate dielectric properties. To address this limitation, this study proposes a CPT system designed to operate with a single-layer tissue phantom that closely mimics the dielectric characteristics of human tissue. The system is integrated with a class-E LCCL resonant topology to enhance power transfer efficiency. In addition to evaluating performance, this work also investigates safety aspects in terms of electric field emission and specific absorption rate (SAR). Simulations using MATLAB Simulink and ANSYS HFSS reveal that at a 1 mm tissue gap, the electric field reaches 298.09 V/m and the SAR is 1.14 W/kg, which are both within established safety limits (614 V/m and 2 W/kg per 10 g of tissue). Furthermore, a 5 W, 1 MHz system operating across a 2 mm tissue gap demonstrates power transfer efficiencies of 40.61% for skin tissue and 20.53% for muscle tissue. These results validate the system’s safety and efficiency for powering deeply implanted biomedical devices.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24157</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v17.i1.pp502-517</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 17, No 1: March 2026; 502-517</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v17.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/24157/15182</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Yusmarnita Yusop, Amy Sarah Ngu, Cheok Yan Qi, N. B. Asan, Huzaimah Husin, Shakir Saat, Peter Adam Hoeher</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>