Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Effect analysis of residual magnetism availability level on the success of voltage generation processes in self-excited induction generators

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 3 (2020) · hlm. 1211–1219

DOI
10.11591/ijpeds.v11.i3.pp1211-1219
ISSN
2722-256X, 2088-8694
Terbit
2020-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The voltage generation process is a very crucial initial stage for the successful operation of the self-excited induction generator (SEIG). The availability of residual magnetism and the adequacy of excitation capacitor value are factors that determine the success of the voltage generation process on the SEIG. This paper analyzes the effect of the availability of residual magnetism on the rotor's magnetic core. With a simple approach, the terminal voltage on the SEIG can be solved through the intersection between the magnetization curve (Xm) and the excitation curve (Xce). The shape and equation of the magnetization curve will be affected by the availability of residual magnetism. The change in residual magnetism availability will cause a change in the intersection point between the magnetization curve (Xm) and the excitation curve (Xce), which will determine the value of voltage generated by the generator. In this study, Newton Rhapson's method with numerical iteration approach has been used to analyze the effect of changes in the availability of residual magnetism on the success of voltage generation on the SEIG. The analysis results have been shown that the availability of residual magnetism with residual voltage values below 1.04 Volt will cause the failure of the SEIG to generate the terminal voltage at its nominal value. Meanwhile, the availability of residual magnetism in SEIG with residual voltage values above 1.04 Volt, will succeed in generating terminal voltage at its nominal value. For SEIG used as the object of this study, the value of Eres = 1.04 Volt is a critical value of the availability of residual magnetism.

Jaringan kolaborasi para penulis

40 penulis · 97 tautan kepenulisan bersama · 26 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • Medan Area University
  • Universiti Malaysia Perlis
  • Universitas Negeri Padang
  • University of Bangka Belitung
  • Riau University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Habib SatriaMedan Area University8
Indri DayanaMedan Area University4
Muhammad Imran HamidAndalas University4
Axel DorizaAndalas University4
Moranain MungkinMedan Area University3
Dadan RamdanMedan Area University3
Dina MaizanaMedan Area University3
Muhammad Fadlan SiregarMedan Area University3
Nukhe Andri SilvianaMedan Area University2
Novizon NovizonAndalas University2
Rahmad B. Y. SyahMedan Area University2
Krismadinata KrismadinataUniversitas Negeri Padang2
Muhammad Imran HamidAndalas University2
Rahmad SyahMedan Area University1
Abdul RajabAndalas University1
Hanalde AndreAndalas University1
Baharuddin BaharuddinAndalas University1
Harry GumilangAfiliasi tidak diketahui1
Thoriq Kurnia AgungAndalas University1
Dawam HabibullahAndalas University1
Muhammad IrwantoUniversiti Malaysia Perlis1
Benny Dwika LeonandaAndalas University1
Rindina ArmysaAndalas University1
Syukron Al- FajriAndalas University1
Farah AzizahAndalas University1
Iqbal SalfikriAndalas University1
Wahyu PrabowoAndalas University1
Syafii GhazaliAfiliasi tidak diketahui1
Muzamir IsaUniversiti Malaysia Perlis1
Muhammad Yonggi PurizaUniversity of Bangka Belitung1
Azriyenni Azhari ZakriRiau University1
Muhammad Ridha FauziAndalas University1
Imra Nur IzrillahAndalas University1
Ricky MaulanaAndalas University1
Aulia AuliaAndalas University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Effect analysis of residual magnetism availability level on the success of voltage generation processes in self-excited induction generators</dc:title>
	<dc:creator>Nazir, Refdinal</dc:creator>
	<dc:creator>Syafii, Syafii</dc:creator>
	<dc:creator>Pawawoi, Andi</dc:creator>
	<dc:creator>Akbar, Fajril</dc:creator>
	<dc:creator>Arfan, Yudi</dc:creator>
	<dc:description xml:lang="en-US">The voltage generation process is a very crucial initial stage for the successful operation of the self-excited induction generator (SEIG). The availability of residual magnetism and the adequacy of excitation capacitor value are factors that determine the success of the voltage generation process on the SEIG. This paper analyzes the effect of the availability of residual magnetism on the rotor's magnetic core. With a simple approach, the terminal voltage on the SEIG can be solved through the intersection between the magnetization curve (Xm) and the excitation curve (Xce). The shape and equation of the magnetization curve will be affected by the availability of residual magnetism. The change in residual magnetism availability will cause a change in the intersection point between the magnetization curve (Xm) and the excitation curve (Xce), which will determine the value of voltage generated by the generator. In this study, Newton Rhapson's method with numerical iteration approach has been used to analyze the effect of changes in the availability of residual magnetism on the success of voltage generation on the SEIG. The analysis results have been shown that the availability of residual magnetism with residual voltage values below 1.04 Volt will cause the failure of the SEIG to generate the terminal voltage at its nominal value. Meanwhile, the availability of residual magnetism in SEIG with residual voltage values above 1.04 Volt, will succeed in generating terminal voltage at its nominal value. For SEIG used as the object of this study, the value of Eres = 1.04 Volt is a critical value of the availability of residual magnetism.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">Andalas University</dc:contributor>
	<dc:date>2020-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20525</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i3.pp1211-1219</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 3: September 2020; 1211-1219</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20525/13167</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Refdinal Nazir, Syafii Syafii, Andi Pawawoi, Fajril Akbar, Yudi Arfan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>