Reduction in Cogging Torque and Flux per Pole in BLDC Motor by Adapting U-Clamped Magnetic Poles

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 1 (2017) · hlm. 297–304

DOI
10.11591/ijpeds.v8.i1.pp297-304
ISSN
2722-256X, 2088-8694
Terbit
2017-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

A Permanent Magnet BLDC motor is designed for reduction in cogging torque and flux per pole. The cogging torque causes direct impact in permanent magnet BLDC motor performance by causing torque ripple problems. This paper proposes a new method for reducing cogging torque by adapting to U-clamped magnetic poles. Finite Element Analysis (FEA) is used to calculate the cogging torque and the flux per pole for different shapes of magnetic pole. It can be shown that the cogging torque could be greatly reduced by adapting to U-clamped magnetic poles. At the same time it is found that the flux per pole is also considerably reduced. The effectiveness of the proposed method is verified by comparing the cogging torque and flux per pole for various designs available in the literature.

Jaringan kolaborasi para penulis

20 penulis · 56 tautan kepenulisan bersama · 26 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • SRM University
  • Ford Motor Company (United States)
  • Amrita Vishwa Vidyapeetham
  • Government of Tamil Nadu
  • King Abdulaziz University
  • SRM Institute of Science and Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
K. MohanrajSRM University3
V. KalyanasundaramSRM Institute of Science and Technology2
Bharathi Mohan GurusamyAmrita Vishwa Vidyapeetham1
R Prasanna KumarAmrita Vishwa Vidyapeetham1
Gayathri MuthurasuGovernment of Tamil Nadu1
Rithani MohanAmrita Vishwa Vidyapeetham1
Gundala PallaviAmrita Vishwa Vidyapeetham1
Ali A. AltalbeKing Abdulaziz University1
T. GunasekharAfiliasi tidak diketahui1
D. MeenuAfiliasi tidak diketahui1
M. AnushaAfiliasi tidak diketahui1
Sayantan BhattacharjeeSRM University1
Maulik TiwariSRM University1
Devashish VashishthaSRM University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Reduction in Cogging Torque and Flux per Pole in BLDC Motor by Adapting U-Clamped Magnetic Poles</dc:title>
	<dc:creator>Noyal Doss, M. Arun</dc:creator>
	<dc:creator>Vijayakumar, S.</dc:creator>
	<dc:creator>Mohideen, A. Jamal</dc:creator>
	<dc:creator>Kannan, K. Sathiah</dc:creator>
	<dc:creator>Sairam, N.D. Balaji</dc:creator>
	<dc:creator>Karthik, K.</dc:creator>
	<dc:description xml:lang="en-US">A Permanent Magnet BLDC motor is designed for reduction in cogging torque and flux per pole. The cogging torque causes direct impact in permanent magnet BLDC motor performance by causing torque ripple problems. This paper proposes a new method for reducing cogging torque by adapting to U-clamped magnetic poles. Finite Element Analysis (FEA) is used to calculate the cogging torque and the flux per pole for different shapes of magnetic pole. It can be shown that the cogging torque could be greatly reduced by adapting to U-clamped magnetic poles. At the same time it is found that the flux per pole is also considerably reduced. The effectiveness of the proposed method is verified by comparing the cogging torque and flux per pole for various designs available in the literature.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2017-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6159</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i1.pp297-304</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 1: March 2017; 297-304</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6159/6007</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 M. Arun Noyal Doss, S. Vijayakumar, A. Jamal Mohideen, K. Sathiah Kannan, N.D. Balaji Sairam, K. Karthik</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>