Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Renewable energy generation system connected to micro grid and analysis of energy management: a critical review

International Journal of Power Electronics and Drive Systems · Vol. 13 No. 1 (2022) · hlm. 470–479

DOI
10.11591/ijpeds.v13.i1.pp470-479
ISSN
2722-256X, 2088-8694
Terbit
2022-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Renewable energy generations have been employed throughout the world in order to meet the increasing load demand. It is a pollution free and abundantly accessible. The generation cost has been reduced because of more research advancement. Photovoltaic (PV) can’t generate throughout the day due to weather condition. In order to maintain the continuity of power generation a hybrid renewable generation system (HRGS) concept has been considered in this research work. HRGS is an integration of more than one renewable energy which consists of PV, wind, solid oxide fuel cell (SOFC), an auxiliary unit (AU). AU is used as a backup generation which can generate power when all the renewable energy fails to generate. AU may be of diesel generator (DG) or super capacitor. This paper discusses the various parts of HRGS and its comparison. Furthermore, its impact of energy management so as to deliver the energy to the grid in a continuous and reliable manner. Therefore, a detail study of different component of HRGS & renewable energy has been highlighted which will be helpful for the new researchers for advancement of power generation and its control strategy of energy management connected to the grid.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 10 tautan kepenulisan bersama · 5 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • G H Raisoni University
  • KIIT University
  • Veer Surendra Sai University of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Prakash Kumar HotaVeer Surendra Sai University of Technology3
Bhagabat PandaKIIT University2
S. K. MishraG H Raisoni University2
Bhagabata PandaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Renewable energy generation system connected to micro grid and analysis of energy management: a critical review</dc:title>
	<dc:creator>Rathod, Pranita</dc:creator>
	<dc:creator>Mishra, Sanjoy Kumar</dc:creator>
	<dc:creator>Bhuyan, Sujit Kumar</dc:creator>
	<dc:subject xml:lang="en-US">energy management; hybrid renewable energy; lithium batteries; solid oxide fuel cell; super capacitor</dc:subject>
	<dc:description xml:lang="en-US">Renewable energy generations have been employed throughout the world in order to meet the increasing load demand. It is a pollution free and abundantly accessible. The generation cost has been reduced because of more research advancement. Photovoltaic (PV) can’t generate throughout the day due to weather condition. In order to maintain the continuity of power generation a hybrid renewable generation system (HRGS) concept has been considered in this research work. HRGS is an integration of more than one renewable energy which consists of PV, wind, solid oxide fuel cell (SOFC), an auxiliary unit (AU). AU is used as a backup generation which can generate power when all the renewable energy fails to generate. AU may be of diesel generator (DG) or super capacitor. This paper discusses the various parts of HRGS and its comparison. Furthermore, its impact of energy management so as to deliver the energy to the grid in a continuous and reliable manner. Therefore, a detail study of different component of HRGS &amp;amp; renewable energy has been highlighted which will be helpful for the new researchers for advancement of power generation and its control strategy of energy management connected to the grid.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US">no</dc:contributor>
	<dc:date>2022-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21373</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v13.i1.pp470-479</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 1: March 2022; 470-479</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v13.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21373/13745</dc:relation>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/downloadSuppFile/21373/2980</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Pranita Rathod, Sanjoy Kumar Mishra, Sujit Kumar Bhuyan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>