Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Distributed Generation Inverter as APF in Dual APF DG interfacing Scheme

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 3 (2017) · hlm. 1441–1454

DOI
10.11591/ijpeds.v8.i3.pp1441-1454
ISSN
2722-256X, 2088-8694
Terbit
2017-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Power quality issues are the most concerned area for electrical engineers in these modern days due to indusrtrialization and advancements in electronics. Harmonics are one of the power quality issues that deteriorated the quality of source components delivered to load. Active power filters (APF) are the compensating devices used to mitigate harmonics. Distributed generation (DG) became a trendline due to economical, technical and environmental reasons. This paper presents the harmonic compensation using dual APF sharing compensating signals while active power is fed from distributed generation to grid. DG inverter acts as an interface between DG system and grid to feed active power from DG to grid. In this context, the DG inverter acts both as inverter and APF, used as inverter to invert supply from DG and feeds grid for specified time and also as APF for harmonic compensation thereafter along with dual APF. The proposed system is developed and results are obtained using MATLAB/SIMULINK software. Results are shown for DG inverter feeding active power to grid and also acting as APF. Dual APF characteristics are also shown.

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Rayalaseema University
  • Jawaharlal Nehru Technological University, Hyderabad
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
V. Sowmya SreeJawaharlal Nehru Technological University, Hyderabad1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Distributed Generation Inverter as APF in Dual APF DG interfacing Scheme</dc:title>
	<dc:creator>Babu, Yadiki Rajendra</dc:creator>
	<dc:creator>Rao, C. Srinivasa</dc:creator>
	<dc:description xml:lang="en-US">Power quality issues are the most concerned area for electrical engineers in these modern days due to indusrtrialization and advancements in electronics. Harmonics are one of the power quality issues that deteriorated the quality of source components delivered to load. Active power filters (APF) are the compensating devices used to mitigate harmonics. Distributed generation (DG) became a trendline due to economical, technical and environmental reasons. This paper presents the harmonic compensation using dual APF sharing compensating signals while active power is fed from distributed generation to grid. DG inverter acts as an interface between DG system and grid to feed active power from DG to grid. In this context, the DG inverter acts both as inverter and APF, used as inverter to invert supply from DG and feeds grid for specified time and also as APF for harmonic compensation thereafter along with dual APF. The proposed system is developed and results are obtained using MATLAB/SIMULINK software. Results are shown for DG inverter feeding active power to grid and also acting as APF. Dual APF characteristics are also shown.  </dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/7616</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i3.pp1441-1454</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 3: September 2017; 1441-1454</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/7616/7465</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 Yadiki Rajendra Babu, C. Srinivasa Rao</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>