Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Power Quality Analysis of Vienna Rectifier for BLDC Motor Drive Application

International Journal of Power Electronics and Drive Systems · Vol. 7 No. 1 (2016) · hlm. 7–16

DOI
10.11591/ijpeds.v7.i1.pp7-16
ISSN
2722-256X, 2088-8694
Terbit
2016-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents the power quality improvements for a BLDC driver using Vienna rectifier as front end converter. The major drawbacks in the BLDC motor drive and non linear load applications are the line pollution and depreciation of the power factor. The conventional power factor correction method is not economical and efficient. It requires bulky components as load changes and produce high THD and less Power factor. The front end converter of BLDC bridge inverter drive is proposed by the Vienna rectifier, which can contribute more significantly in improving the power factor and reduce the line pollution. The Vienna rectifier topology is controlled by the constant switching frequency control technique for wide range of load variation and it reduces the THD, improve the power factor and provide a steady DC link voltage to the bridge inverter to drive the BLDC motor. The design calculation and performance characteristics of BLDC motor and Vienna rectifier are verified by using Matlab simulation.

Jaringan kolaborasi para penulis

10 penulis · 15 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Anna University, Chennai
  • Vellore Institute of Technology University
  • Escola Superior Aberta do Brasil
  • Sathyabama Institute of Science and Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
K. PalanisamyVellore Institute of Technology University2
R. GovarthananVellore Institute of Technology University1
Ramesh PanduranganVellore Institute of Technology University1
S AnandhAnna University, Chennai1
Paramasivam ParamasivamAfiliasi tidak diketahui1
V. MeenakshiSathyabama Institute of Science and Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Power Quality Analysis of Vienna Rectifier for BLDC Motor Drive Application</dc:title>
	<dc:creator>Srinivasan, K.</dc:creator>
	<dc:creator>Vijayan, S.</dc:creator>
	<dc:creator>Paramasivam, S.</dc:creator>
	<dc:creator>Sundaramoorthi, K.</dc:creator>
	<dc:description xml:lang="en-US">This paper presents the power quality improvements for a BLDC driver using Vienna rectifier as front end converter. The major drawbacks in the BLDC motor drive and non linear load applications are the line pollution and depreciation of the power factor. The conventional power factor correction method is not economical and efficient. It requires bulky components as load changes and produce high THD and less Power factor. The front end converter of BLDC bridge inverter drive is proposed by the Vienna rectifier, which can contribute more significantly in improving the power factor and reduce the line pollution. The Vienna rectifier topology is controlled by the constant switching frequency control technique for wide range of load variation and it reduces the THD, improve the power factor and provide a steady DC link voltage to the bridge inverter to drive the BLDC motor. The design calculation and performance characteristics of BLDC motor and Vienna rectifier are verified by using Matlab simulation.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2016-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/367</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v7.i1.pp7-16</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 7, No 1: March 2016; 7-16</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v7.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/367/192</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 K. Srinivasan, S. Vijayan, S. Paramasivam, K. Sundaramoorthi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>