Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Control of DFIG Stator Voltage on Autonomous Micro Hydro Power Plant

International Journal of Power Electronics and Drive Systems · Vol. 7 No. 2 (2016) · hlm. 498–508

DOI
10.11591/ijpeds.v7.i2.pp498-508
ISSN
2722-256X, 2088-8694
Terbit
2016-06-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

An autonomous micro hydro power plant was proposed to utilize the small hydro power potency as a run-of-river. It consisted of a PMSG, a DFIG, and a converter and should be operated in the off-grid configuration. In a previous research, the DFIG stator voltages couldn’t be controlled. In this paper, the novel control algorithm that is able to maintain the DFIG stator voltages of the autonomous micro hydro power plant in the off-grid configuration is proposed. The control algorithm was proposed to use the actual DFIG stator voltages and currents as feedback signals. The controller was tested by varying three input signals, i.e. the DC-link voltage, the DFIG stator voltage reference, and the external stator load which simulated the off-grid configuration. The result of the simulation showed that the DFIG stator voltages could be controlled and were always in accordance with the reference.

Jaringan kolaborasi para penulis

13 penulis · 23 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Indonesia
  • Universitas Muhammadiyah Jakarta
  • Sultan Agung Islamic University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Abdul HalimUniversity of Indonesia3
Indriarto YuniantoroAfiliasi tidak diketahui2
Rudy SetiabudyAfiliasi tidak diketahui2
Budiyanto BudiyantoUniversitas Muhammadiyah Jakarta2
Feri YusivarAfiliasi tidak diketahui1
Rian SuryadiningratAfiliasi tidak diketahui1
Aries SubiantoroAfiliasi tidak diketahui1
Agus SuprajitnoSultan Agung Islamic University1
Abdul HalimUniversity of Indonesia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Control of DFIG Stator Voltage on Autonomous  Micro Hydro Power Plant</dc:title>
	<dc:creator>Yusivar, Feri</dc:creator>
	<dc:creator>Wicaksono, Nanda Avianto</dc:creator>
	<dc:creator>Subiantoro, Aries</dc:creator>
	<dc:creator>Gunawan, Ridwan</dc:creator>
	<dc:description xml:lang="en-US">An autonomous micro hydro power plant was proposed to utilize the small hydro power potency as a run-of-river. It consisted of a PMSG, a DFIG, and a converter and should be operated in the off-grid configuration. In a previous research, the DFIG stator voltages couldn’t be controlled. In this paper, the novel control algorithm that is able to maintain the DFIG stator voltages of the autonomous micro hydro power plant in the off-grid configuration is proposed. The control algorithm was proposed to use the actual DFIG stator voltages and currents as feedback signals. The controller was tested by varying three input signals, i.e. the DC-link voltage, the DFIG stator voltage reference, and the external stator load which simulated the off-grid configuration. The result of the simulation showed that the DFIG stator voltages could be controlled and were always in accordance with the reference.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:date>2016-06-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/607</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v7.i2.pp498-508</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 7, No 2: June 2016; 498-508</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v7.i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/607/5670</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2016 Feri Yusivar, Nanda Avianto Wicaksono, Aries Subiantoro, Ridwan Gunawan</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>