Akses terbuka
Jurnal
SINTA 1
Reactive power control of grid-connected photovoltaic micro-inverter based on third-harmonic injection
International Journal of Power Electronics and Drive Systems · Vol. 12 No. 4 (2021) · hlm. 2169–2181
ISSN 2722-256X, 2088-8694
Terbit 2021-12-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
This paper presents four interleaved flyback DC-DC converters. Each flyback converter contains a separate maximum power point tracker (MPPT). The MPP tracker is used to collect the maximum power value from photovoltaic panel by using (P&O) algorithm with an output of reference current. In latest years, the active third-harmonic injection circuit have received much interest, this technique contributed to getting a better quality of injection current into the utility grid and control the reactive power. For converting direct current to three-phase sinusoidal currents, a line-commutated current source inverter type (CSI) with filter is used. The developed micro-inverter of (1000 W) offers an expanded range of reactive power control with balanced three-phase output power and good efficiency 95.07%. The effectiveness of the suggested system is clarified through the MATLAB program simulation. The system proposed in this paper has proven its effectiveness in obtaining reactive power control, nearly sinusoidal three-phase output currents and it is compared with the traditional PV micro-inverter system. The comparison shows that the PV micro-inverter is best in more specification than the traditional PV system such as efficiency and total harmonic distortion (THD) and the system losses.
Jaringan kolaborasi para penulis
9 penulis ·
9 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Reactive power control of grid-connected photovoltaic micro-inverter based on third-harmonic injection</dc:title>
<dc:creator>Noori, Farah T.</dc:creator>
<dc:creator>Hassan, Turki K.</dc:creator>
<dc:subject xml:lang="en-US">Current source inverter; Grid-connected; Interleaved flyback; Photovoltaic panel; Third-harmonic injection</dc:subject>
<dc:description xml:lang="en-US">This paper presents four interleaved flyback DC-DC converters. Each flyback converter contains a separate maximum power point tracker (MPPT). The MPP tracker is used to collect the maximum power value from photovoltaic panel by using (P&amp;O) algorithm with an output of reference current. In latest years, the active third-harmonic injection circuit have received much interest, this technique contributed to getting a better quality of injection current into the utility grid and control the reactive power. For converting direct current to three-phase sinusoidal currents, a line-commutated current source inverter type (CSI) with filter is used. The developed micro-inverter of (1000 W) offers an expanded range of reactive power control with balanced three-phase output power and good efficiency 95.07%. The effectiveness of the suggested system is clarified through the MATLAB program simulation. The system proposed in this paper has proven its effectiveness in obtaining reactive power control, nearly sinusoidal three-phase output currents and it is compared with the traditional PV micro-inverter system. The comparison shows that the PV micro-inverter is best in more specification than the traditional PV system such as efficiency and total harmonic distortion (THD) and the system losses.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US"></dc:contributor>
<dc:date>2021-12-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21551</dc:identifier>
<dc:identifier>10.11591/ijpeds.v12.i4.pp2169-2181</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 4: December 2021; 2169-2181</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v12.i4</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21551/13613</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Farah T. Noori, Turki K. Hassan</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Noori, F. T., & Hassan, T. K. (2021). Reactive power control of grid-connected photovoltaic micro-inverter based on third-harmonic injection. International Journal of Power Electronics and Drive Systems, 12(4), 2169–2181. https://doi.org/10.11591/ijpeds.v12.i4.pp2169-2181
Salin
IEEE
F. T. Noori and T. K. Hassan, “Reactive power control of grid-connected photovoltaic micro-inverter based on third-harmonic injection,” International Journal of Power Electronics and Drive Systems, vol. 12, no. 4, pp. 2169–2181, 2021, doi: 10.11591/ijpeds.v12.i4.pp2169-2181.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.