Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Early degradation factors of solar 33 kV grid connected power plant, a comparative study

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 1 (2024) · hlm. 442–453

DOI
10.11591/ijpeds.v15.i1.pp442-453
ISSN
2722-256X, 2088-8694
Terbit
2024-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper identifies and analyses early degradation mechanisms observed in photovoltaic (PV) modules of power plants over 7 years of operation on the coast power grid in Mauritania. Performance degradation takes place due to several reasons such as material degradation following dust accumulation, high temperature, and humidity. Also, mismatch of electric power parameters such as increasing loads above projected values of the plant. Therefore, this paper analyses and studies the degradation in four phases. First, the visual inspection detects the degradation of materials and defects such as the presence of dust, cracks, browning (discoloration), and connection corrosion. The second phase proposes a mathematical model to calculate the early degradation rate (DR) of different components, such as short circuit current (Isc), open circuit voltage (VOC), the maximum yield power (Pmax), and the fill factor (FF) of the PV module. The third phase is a MATLAB modeling of the measured real-time data of the operating PV system to test Power versus voltage curves (with and without degradation) to examine the presence of failure of PV modules. Finally, compare the evolution of real-time production data for three measured years (2015, 2016, and 2017) with the simulation curves of this study.

Kata kunci

Jaringan kolaborasi para penulis

32 penulis · 104 tautan kepenulisan bersama · 48 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Université de Nouakchott
  • University of Anbar
  • Cheikh Anta Diop University
  • Université Larbi Tébessi
  • Northern Technical University
  • Middle Technical University
  • École Normale Supérieure de Nouakchott
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Abdel Kader MahmoudUniversité de Nouakchott4
Abdullah Khalid AhmedUniversity of Anbar2
Ahmed Med YahyaAfiliasi tidak diketahui2
Nadhira KhezamUniversity of Carthage2
Zaid Hussien AliNorthern Technical University1
Mohammed Kareem MohammedUniversity of Anbar1
Firas Fadhil SalihUniversity of Anbar1
Falah Noori Saeed Al-dulaimiMiddle Technical University1
Soukeyna MohamedUniversité de Nouakchott1
Vatma ElvallyUniversité de Nouakchott1
Emel KiyanAfiliasi tidak diketahui1
Cheibany Cheikh EbeyaUniversité de Nouakchott1
Mohamed Mahmoud AliUniversité de Nouakchott1
Mamoudou NdongoUniversité de Nouakchott1
Ahmed SidibbaÉcole Normale Supérieure de Nouakchott1
Kaan YetilmezsoyYıldız Technical University1
Boudy BilalAfiliasi tidak diketahui1
Eslemhoum JedouUniversité de Nouakchott1
Halima Maiguizo DiagneCheikh Anta Diop University1
Cheikhani Abdel KaderUniversité de Nouakchott1
Mohamed El Mamy Mohamed MahmoudUniversité de Nouakchott1
Beibah GleigumeUniversité de Nouakchott1
Amer Tayes SaeedUniversity of Tikrit1
Ahmed Subhi AbdalkaforUniversity of Anbar1
Mustafa Hamid Al-JumailiUniversity of Anbar1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Early degradation factors of solar 33 kV grid connected power plant, a comparative study</dc:title>
	<dc:creator>Elhassene, Issa Cheikh</dc:creator>
	<dc:creator>El Heiba, Bamba</dc:creator>
	<dc:creator>Taha, Mohammed Qasim</dc:creator>
	<dc:creator>Mahmoud, Teyeb Med</dc:creator>
	<dc:creator>Aoulmi, Zoubir</dc:creator>
	<dc:creator>Youm, Issakha</dc:creator>
	<dc:creator>Mahmoud, Abdelkader</dc:creator>
	<dc:subject xml:lang="en-US">degradation rate; early degradation; grid-tied PV system; PV module inspection; solar power plant</dc:subject>
	<dc:description xml:lang="en-US">This paper identifies and analyses early degradation mechanisms observed in photovoltaic (PV) modules of power plants over 7 years of operation on the coast power grid in Mauritania. Performance degradation takes place due to several reasons such as material degradation following dust accumulation, high temperature, and humidity. Also, mismatch of electric power parameters such as increasing loads above projected values of the plant. Therefore, this paper analyses and studies the degradation in four phases. First, the visual inspection detects the degradation of materials and defects such as the presence of dust, cracks, browning (discoloration), and connection corrosion. The second phase proposes a mathematical model to calculate the early degradation rate (DR) of different components, such as short circuit current (Isc), open circuit voltage (VOC), the maximum yield power (Pmax), and the fill factor (FF) of the PV module. The third phase is a MATLAB modeling of the measured real-time data of the operating PV system to test Power versus voltage curves (with and without degradation) to examine the presence of failure of PV modules. Finally, compare the evolution of real-time production data for three measured years (2015, 2016, and 2017) with the simulation curves of this study.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22277</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i1.pp442-453</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 1: March 2024; 442-453</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22277/14440</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Mohammed Qasim Taha</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>