Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Adaptive fuzzy PID integrated renewable power management system for off grid and on grid conditions

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 4 (2024) · hlm. 2580–2590

DOI
10.11591/ijpeds.v15.i4.pp2580-2590
ISSN
2722-256X, 2088-8694
Terbit
2024-12-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Renewable source penetration into the distribution grid is merely a greater challenge as the powers from renewable sources are not stable and constant. Due to their sporadic operating states the power shared to the grid creates power quality issues. Therefore, an efficient adaptive PMA needs to be adopted for the control of these renewable sources, which controls the power extraction of these sources. For standard power sharing to the variable loads in the grid islanding state, the renewable sources are updated with the ESS module. In this paper, a low-rating distribution test system is considered connected with different renewable sources PV sources, wind farms, and fuel cell plants sharing renewable power. The PV source module is updated with AF-PID replacing the PI controller integrated PMA and ESS module for extensive control of the power of the generation unit during any operating condition. The DC and AC voltages are more stabilized by the upgraded PMA during grid islanding conditions. Mitigation of ripple and harmonic content is achieved by the AF-PID controller varying the proportional, integral, and derivative gains as per the error signal generated. A comparative analysis is carried out on the system validating the effectiveness of the AF-PID controller using MATLAB Simulink software.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 12 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Visvesvaraya Technological University
  • Annamalai University
  • Bapuji Institute of Engineering and Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Basavarajappa Sokke RameshappaVisvesvaraya Technological University1
Ujwala GajulaAnnamalai University1
Gouthami EragamreddyVisvesvaraya Technological University1
N. Malla ReddyAfiliasi tidak diketahui1
Remala Geshma KumariAnnamalai University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Adaptive fuzzy PID integrated renewable power management system for off grid and on grid conditions</dc:title>
	<dc:creator>Gopu, Veeranjaneyulu</dc:creator>
	<dc:creator>Nagaraj, Mudakapla Shadaksharappa</dc:creator>
	<dc:subject xml:lang="en-US">AF-PID; energy storage system; MATLAB; photovoltaic; power management algorithm</dc:subject>
	<dc:description xml:lang="en-US">Renewable source penetration into the distribution grid is merely a greater challenge as the powers from renewable sources are not stable and constant. Due to their sporadic operating states the power shared to the grid creates power quality issues. Therefore, an efficient adaptive PMA needs to be adopted for the control of these renewable sources, which controls the power extraction of these sources. For standard power sharing to the variable loads in the grid islanding state, the renewable sources are updated with the ESS module. In this paper, a low-rating distribution test system is considered connected with different renewable sources PV sources, wind farms, and fuel cell plants sharing renewable power. The PV source module is updated with AF-PID replacing the PI controller integrated PMA and ESS module for extensive control of the power of the generation unit during any operating condition. The DC and AC voltages are more stabilized by the upgraded PMA during grid islanding conditions. Mitigation of ripple and harmonic content is achieved by the AF-PID controller varying the proportional, integral, and derivative gains as per the error signal generated. A comparative analysis is carried out on the system validating the effectiveness of the AF-PID controller using MATLAB Simulink software.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23344</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i4.pp2580-2590</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 4: December 2024; 2580-2590</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23344/14816</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 VEERANJANEYULU GOPU, Dr.M.S. NAGARAJ</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>