Akses terbuka
Jurnal
SINTA 1
Study of novel parallel H-bridge and common-emitter current-source inverters for photovoltaic power conversion system
International Journal of Power Electronics and Drive Systems · Vol. 13 No. 1 (2022) · hlm. 500–508
ISSN 2722-256X, 2088-8694
Terbit 2022-03-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
A novel operation of three-level H-bridge and common-emitter current source inverters (CSIs) proposed for photovoltaic power converters is presented in this paper. Two photovoltaic systems with two different inverter circuits, i.e. H-bridge and common-emitter CSIs, were connected in parallel to supply a sharing ac power load. In order to regulate the power supplied by each inverter system, proportional integral current controllers were employed. Triangular carrier and sinusoidal signals-based modulation techniques were implemented to both inverters. Some parameters such as load current, inverter’s output current, total harmonics distortion (THD), and efficiency were tested and analyzed. Test results showed that in the parallel operation of these inverters, the average THD percentage of the load current was 0.34% for load power factor 0.996 and 0.62 % for load power factor 0.782. Minimum waveform distortion of inverter ac currents during parallel operation can be achieved if the current magnitudes of both inverters were set the same. In the case of efficiency, the maximum efficiency of the system was 89.07%. Operating the H-bridge CSI with a higher magnitude of the output current will result in higher efficiency of the system.
Jaringan kolaborasi para penulis
14 penulis ·
38 tautan kepenulisan bersama
· 14 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Jenderal Soedirman University Tun Hussein Onn University of Malaysia Shizuoka University
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 8 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Study of novel parallel H-bridge and common-emitter current-source inverters for photovoltaic power conversion system</dc:title>
<dc:creator>Suroso, Suroso</dc:creator>
<dc:creator>Siswantoro, Hari</dc:creator>
<dc:subject xml:lang="en-US">inverter; parallel operation; photovoltaic</dc:subject>
<dc:description xml:lang="en-US">A novel operation of three-level H-bridge and common-emitter current source inverters (CSIs) proposed for photovoltaic power converters is presented in this paper. Two photovoltaic systems with two different inverter circuits, i.e. H-bridge and common-emitter CSIs, were connected in parallel to supply a sharing ac power load. In order to regulate the power supplied by each inverter system, proportional integral current controllers were employed. Triangular carrier and sinusoidal signals-based modulation techniques were implemented to both inverters. Some parameters such as load current, inverter’s output current, total harmonics distortion (THD), and efficiency were tested and analyzed. Test results showed that in the parallel operation of these inverters, the average THD percentage of the load current was 0.34% for load power factor 0.996 and 0.62 % for load power factor 0.782. Minimum waveform distortion of inverter ac currents during parallel operation can be achieved if the current magnitudes of both inverters were set the same. In the case of efficiency, the maximum efficiency of the system was 89.07%. Operating the H-bridge CSI with a higher magnitude of the output current will result in higher efficiency of the system.</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US">Jenderal Soedirman University</dc:contributor>
<dc:date>2022-03-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21477</dc:identifier>
<dc:identifier>10.11591/ijpeds.v13.i1.pp500-508</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 13, No 1: March 2022; 500-508</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v13.i1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21477/13748</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Suroso Suroso, Hari Siswantoro</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Suroso, S., & Siswantoro, H. (2022). Study of novel parallel H-bridge and common-emitter current-source inverters for photovoltaic power conversion system. International Journal of Power Electronics and Drive Systems, 13(1), 500–508. https://doi.org/10.11591/ijpeds.v13.i1.pp500-508
Salin
IEEE
S. Suroso and H. Siswantoro, “Study of novel parallel H-bridge and common-emitter current-source inverters for photovoltaic power conversion system,” International Journal of Power Electronics and Drive Systems, vol. 13, no. 1, pp. 500–508, 2022, doi: 10.11591/ijpeds.v13.i1.pp500-508.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.