Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Effects of shorter phase-resolved partial discharge duration on PD classification accuracy

International Journal of Power Electronics and Drive Systems · Vol. 11 No. 1 (2020) · hlm. 326–332

DOI
10.11591/ijpeds.v11.i1.pp326-332
ISSN
2722-256X, 2088-8694
Terbit
2020-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Partial discharge (PD) pattern recognition is useful to diagnose insulation condition. PD measurement data is commonly represented in phase-resolved partial discharge (PRPD) format. PRPD is useful as it provides a visible pattern for different PD source and various features can be extracted for PD pattern recognition. Shorter PRPD duration will enable more training data but the information in each data is less and vice versa. This works aims to investigate the effects of using very short duration PRPD data on the accuracy of PD pattern recognition. The results conclude that machine learning models such as Artificial Neural Network (ANN) and Support Vector Machine (SVM) are robust enough such that reduction of PRPD duration from 15-seconds to 1-second causes less than 5 % drop in the classification accuracy. However, this is only true for noise free condition. When the same PD data is overlapped with random noise, the classification accuracy suffers a significant reduction up to 19%. Therefore, longer PRPD duration is recommended to withstand the effects of noise contamination.

Jaringan kolaborasi para penulis

12 penulis · 28 tautan kepenulisan bersama · 18 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tunku Abdul Rahman University of Management and Technology
  • University of Malaya
  • Université de ain Témouchent
  • Université Mustapha Stambouli de Mascara
  • Centre Universitaire Nour Bachir El Bayadh
  • Ahmed Zabana University - Relizane
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Hafidha ReriballahAhmed Zabana University - Relizane1
Fatima Zohra BoudjellaUniversité de ain Témouchent1
Souhila BoudjellaUniversité Mustapha Stambouli de Mascara1
Nasiru Yahaya AhmedUniversity of Malaya1
Smail LatifaCentre Universitaire Nour Bachir El Bayadh1
Kin Yun LumTunku Abdul Rahman University of Management and Technology1
Jyi Shyan ChowTunku Abdul Rahman University of Management and Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Effects of shorter phase-resolved partial discharge duration on PD classification accuracy</dc:title>
	<dc:creator>Xin, Chong Wan</dc:creator>
	<dc:creator>Raymond, Wong Jee Keen</dc:creator>
	<dc:creator>Illias, Hazlee Azil</dc:creator>
	<dc:creator>Kin, Lai Weng</dc:creator>
	<dc:creator>Haur, Yiauw Kah</dc:creator>
	<dc:description xml:lang="en-US">Partial discharge (PD) pattern recognition is useful to diagnose insulation condition. PD measurement data is commonly represented in phase-resolved partial discharge (PRPD) format. PRPD is useful as it provides a visible pattern for different PD source and various features can be extracted for PD pattern recognition. Shorter PRPD duration will enable more training data but the information in each data is less and vice versa. This works aims to investigate the effects of using very short duration PRPD data on the accuracy of PD pattern recognition. The results conclude that machine learning models such as Artificial Neural Network (ANN) and Support Vector Machine (SVM) are robust enough such that reduction of PRPD duration from 15-seconds to 1-second causes less than 5 % drop in the classification accuracy. However, this is only true for noise free condition. When the same PD data is overlapped with random noise, the classification accuracy suffers a significant reduction up to 19%. Therefore, longer PRPD duration is recommended to withstand the effects of noise contamination.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2020-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20479</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v11.i1.pp326-332</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 11, No 1: March 2020; 326-332</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v11.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/20479/13003</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Chong Wan Xin, Wong Jee Keen Raymond, Hazlee Azil Illias, Lai Weng Kin, Yiauw Kah Haur</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>