Akses terbuka
Jurnal
SINTA 1
A novel fetal Doppler calibrator: enhancing the precision of fetal heart rate monitoring
International Journal of Power Electronics and Drive Systems · Vol. 16 No. 2 (2025) · hlm. 873–881
ISSN 2722-256X, 2088-8694
Terbit 2025-06-01
Penerbit Institute of Advanced Engineering and Science
Bahasa eng
Abstrak
The congenital heart disease is associated with abnormal brain development in the womb of pregnant women where fetuses with congenital heart disease are at higher risk of miscarriage compared to the general population. Fetal and neonatal risk identification and assessment are essential for comprehensive risk stratification after diagnosis of congenital heart disease. This study aims to improve the accuracy of Doppler fetal measurements in the diagnosis of congenital heart disease risk with calibrators. This study used an experiment of a calibrator with four push buttons embedded to increase and decrease the beat per minute (BPM) value by comparing the BPM value of the Doppler fetal. The measurement was carried out by comparing the values of the calibrator and the Doppler fetal with units and tens of BPM. Statistical analysis used the paired sample T-Test. The measurement obtained a significant p-value of <0.05 with 95% CI. Furthermore, this calibrator does not have a difference in accuracy level with a Doppler fetal. This states that the calibrator has the feasibility to calibrate the fetal Doppler in the fetal heart examination service for pregnant women. This study has the prospect of improving the technology with the embedding of the internet of things (IoT).
Jaringan kolaborasi para penulis
4 penulis ·
5 tautan kepenulisan bersama
· 1 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universitas PGRI Yogyakarta Muhammadiyah University of Surakarta Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulis Organisasi Artikel bersama
Angger Maharesi Afiliasi tidak diketahui 2
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">A novel fetal Doppler calibrator: enhancing the precision of fetal heart rate monitoring</dc:title>
<dc:creator>Fauzi, Ekha Rifki</dc:creator>
<dc:creator>Setiyadi, Noor Alis</dc:creator>
<dc:creator>Doungjan, Kamonthip</dc:creator>
<dc:subject xml:lang="en-US">Beat per minute; calibrator; congenital heart disease; fetal Doppler; pregnant women</dc:subject>
<dc:description xml:lang="en-US">The congenital heart disease is associated with abnormal brain development in the womb of pregnant women where fetuses with congenital heart disease are at higher risk of miscarriage compared to the general population. Fetal and neonatal risk identification and assessment are essential for comprehensive risk stratification after diagnosis of congenital heart disease. This study aims to improve the accuracy of Doppler fetal measurements in the diagnosis of congenital heart disease risk with calibrators. This study used an experiment of a calibrator with four push buttons embedded to increase and decrease the beat per minute (BPM) value by comparing the BPM value of the Doppler fetal. The measurement was carried out by comparing the values of the calibrator and the Doppler fetal with units and tens of BPM. Statistical analysis used the paired sample T-Test. The measurement obtained a significant p-value of &lt;0.05 with 95% CI. Furthermore, this calibrator does not have a difference in accuracy level with a Doppler fetal. This states that the calibrator has the feasibility to calibrate the fetal Doppler in the fetal heart examination service for pregnant women. This study has the prospect of improving the technology with the embedding of the internet of things (IoT).</dc:description>
<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
<dc:contributor xml:lang="en-US">Direktorat Jenderal Pendidikan Tinggi, Ministry of Education and Culture of the Republic of Indonesia</dc:contributor>
<dc:date>2025-06-01</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:type xml:lang="en-US"></dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23780</dc:identifier>
<dc:identifier>10.11591/ijpeds.v16.i2.pp873-881</dc:identifier>
<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 16, No 2: June 2025; 873-881</dc:source>
<dc:source>2722-256X</dc:source>
<dc:source>2088-8694</dc:source>
<dc:source>10.11591/ijpeds.v16.i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/23780/14915</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2025 Ekha Rifki Fauzi, Noor Alis Setiyadi, Kamonthip Doungjan</dc:rights>
<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Fauzi, E. R., Setiyadi, N. A., & Doungjan, K. (2025). A novel fetal Doppler calibrator: enhancing the precision of fetal heart rate monitoring. International Journal of Power Electronics and Drive Systems, 16(2), 873–881. https://doi.org/10.11591/ijpeds.v16.i2.pp873-881
Salin
IEEE
E. R. Fauzi, N. A. Setiyadi, and K. Doungjan, “A novel fetal Doppler calibrator: enhancing the precision of fetal heart rate monitoring,” International Journal of Power Electronics and Drive Systems, vol. 16, no. 2, pp. 873–881, 2025, doi: 10.11591/ijpeds.v16.i2.pp873-881.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.