Effect of GA based PID controller in bidirectional converter

International Journal of Power Electronics and Drive Systems · Vol. 15 No. 3 (2024) · hlm. 1757–1766

DOI
10.11591/ijpeds.v15.i3.pp1757-1766
ISSN
2722-256X, 2088-8694
Terbit
2024-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The bi-directional direct current to direct current (DC-DC) converter plays a crucial role in applications involving photovoltaic (PV)-based micro grids. These PV-based hybrid systems have become imperative to ensure uninterrupted power supply and meet local power demands. Selecting the right controller for this converter presents a significant challenge. Traditional proportional integral derivative (PID) controllers yield suboptimal efficiency due to their high delay and settling times. This issue can be overcome by implementing a PID controller based on genetic algorithms (GA). An interconnected grid system is employed to regulate the DC connection voltage across various load conditions, with PV serving as the means to sustain electricity generation. Numerous operational modes tailored to demand are explored, and control techniques are used to maintain the desired DC link voltage level, ultimately enhancing the efficiency of both the PV system and the bidirectional converter in on-grid configurations.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 16 tautan kepenulisan bersama · 9 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • AMET University
  • Saveetha University
  • C. Abdul Hakeem College (Autonomous)
  • Sathyabama Institute of Science and Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Satish KumarSathyabama Institute of Science and Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Effect of GA based PID controller in bidirectional converter</dc:title>
	<dc:creator>Kumar, S. Satish</dc:creator>
	<dc:creator>Bharathi, K.</dc:creator>
	<dc:creator>Mohan, S. B.</dc:creator>
	<dc:creator>Balakrishnan, T. Suresh</dc:creator>
	<dc:creator>Kumar, J. Anish</dc:creator>
	<dc:creator>Kumar, M. Sasi</dc:creator>
	<dc:subject xml:lang="en-US">BDC; delay time; fuzzy logic controller; GA-PID; voltage gain</dc:subject>
	<dc:description xml:lang="en-US">The bi-directional direct current to direct current (DC-DC) converter plays a crucial role in applications involving photovoltaic (PV)-based micro grids. These PV-based hybrid systems have become imperative to ensure uninterrupted power supply and meet local power demands. Selecting the right controller for this converter presents a significant challenge. Traditional proportional integral derivative (PID) controllers yield suboptimal efficiency due to their high delay and settling times. This issue can be overcome by implementing a PID controller based on genetic algorithms (GA). An interconnected grid system is employed to regulate the DC connection voltage across various load conditions, with PV serving as the means to sustain electricity generation. Numerous operational modes tailored to demand are explored, and control techniques are used to maintain the desired DC link voltage level, ultimately enhancing the efficiency of both the PV system and the bidirectional converter in on-grid configurations.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2024-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22997</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v15.i3.pp1757-1766</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 15, No 3: September 2024; 1757-1766</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v15.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/22997/14641</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2024 SATISH KUMAR S, Bharathi K, Sasikumar M</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>