Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Asymmetrical four-wire cascaded h-bridge multi-level inverter based shunt active power filter supplied by a photovoltaic source

International Journal of Power Electronics and Drive Systems · Vol. 12 No. 3 (2021) · hlm. 1673–1686

DOI
10.11591/ijpeds.v12.i3.pp1673-1686
ISSN
2722-256X, 2088-8694
Terbit
2021-09-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This paper presents a novel shunt active power filter (SAPF). The power converter that is used in this SAPF is constructed from a four-leg asymmetric multi-level cascaded H-bridge (CHB) inverter that is fed from a photovoltaic source. A three-dimensional space vector modulation (3D-SVPWM) technique is adopted in this work. The multi-level inverter can generate 27-level output with harmonic content is almost zero. In addition to the capability to inject reactive power and mitigating the harmonics, the proposed SAPF has also, the ability to inject real power as it is fed from a PV source. Moreover, it has a fault-tolerant capability that makes the SAPF maintaining its operation under a loss of one leg of the multi-level inverter due to an open-circuit fault without any degradation in the performance. The proposed SAPF is designed and simulated in MATLAB SIMULINK using a single nonlinear load and the results have shown a significant reduction in total harmonics distortion (THD) of the source current under the normal operating condition and post a failure in one phase of the SAPF. Also, similar results are obtained when IEEE 15 bus network is used.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 3 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • An-Najah National University
  • University of Nottingham
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mark SumnerUniversity of Nottingham4
Ameen MadiAn-Najah National University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Asymmetrical four-wire cascaded h-bridge multi-level inverter based shunt active power filter supplied by a photovoltaic source</dc:title>
	<dc:creator>Saleh, Kamel</dc:creator>
	<dc:creator>Mahmoud, Omar</dc:creator>
	<dc:subject xml:lang="en-US">Fault-tolerant; Multi-level inverter; PV system; SAPF</dc:subject>
	<dc:description xml:lang="en-US">This paper presents a novel shunt active power filter (SAPF). The power converter that is used in this SAPF is constructed from a four-leg asymmetric multi-level cascaded H-bridge (CHB) inverter that is fed from a photovoltaic source. A three-dimensional space vector modulation (3D-SVPWM) technique is adopted in this work. The multi-level inverter can generate 27-level output with harmonic content is almost zero. In addition to the capability to inject reactive power and mitigating the harmonics, the proposed SAPF has also, the ability to inject real power as it is fed from a PV source. Moreover, it has a fault-tolerant capability that makes the SAPF maintaining its operation under a loss of one leg of the multi-level inverter due to an open-circuit fault without any degradation in the performance. The proposed SAPF is designed and simulated in MATLAB SIMULINK using a single nonlinear load and the results have shown a significant reduction in total harmonics distortion (THD) of the source current under the normal operating condition and post a failure in one phase of the SAPF. Also, similar results are obtained when IEEE 15 bus network is used.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2021-09-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21457</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v12.i3.pp1673-1686</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 12, No 3: September 2021; 1673-1686</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v12.i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/21457/13508</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Kamel Saleh, Omar Mahmoud</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>