Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

A New Compensation Control Strategy for Grid-connected Wind Turbine and Fuel Cell Inverters in a Microgrid

International Journal of Power Electronics and Drive Systems · Vol. 8 No. 1 (2017) · hlm. 272–278

DOI
10.11591/ijpeds.v8.i1.pp272-278
ISSN
2722-256X, 2088-8694
Terbit
2017-03-01
Penerbit
Institute of Advanced Engineering and Science
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The use of a new control method for grid-connected inverters for reducing the output current harmonic distortion in a wide range of grid-connected distributed generation (DG) applications, including wind turbine (WT) and fuel cell (FC) inverters is proposed in this paper. The control method designed to eliminate main harmonics in a microgrid (MG) and between MG and point of common coupling (PCC) and responsible for the correction of the system unbalance. Another advantage of the proposed control method is that it can be easily adopted into the DG control system without the installation of extra hardware. The proposed control method is comprised of the synchronous reference frame method (SRF). Results from the proposed control method are provided to show the feasibility of the proposed approach.

Jaringan kolaborasi para penulis

13 penulis · 31 tautan kepenulisan bersama · 15 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Politeknik Negeri Ujung Pandang
  • Swinburne University of Technology
  • Islamic Azad University, Firoozkooh Branch
  • University of Nottingham
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohd Wazir MustafaUniversity of Technology Malaysia1
Makmur SainiPoliteknik Negeri Ujung Pandang1
A. R. SultanPoliteknik Negeri Ujung Pandang1
Rusdi NurPoliteknik Negeri Ujung Pandang1
Nur Huda. M TambiSwinburne University of Technology1
Kamyar MehranzamirUniversity of Nottingham1
Jubaer AhmedSwinburne University of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ijpeds.iaescore.com/index.php/IJPEDS/oai, pertama di-harvest 8 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A New Compensation Control Strategy for Grid-connected Wind Turbine and Fuel Cell Inverters in a Microgrid</dc:title>
	<dc:creator>Naderipour, A.</dc:creator>
	<dc:creator>Mohd Zin, A. A.</dc:creator>
	<dc:creator>Habibuddin, M. H.</dc:creator>
	<dc:creator>Moradi, M.</dc:creator>
	<dc:creator>Miveh, M.</dc:creator>
	<dc:creator>Afrouzi, H. N.</dc:creator>
	<dc:description xml:lang="en-US">The use of a new control method for grid-connected inverters for reducing the output current harmonic distortion in a wide range of grid-connected distributed generation (DG) applications, including wind turbine (WT) and fuel cell (FC) inverters is proposed in this paper. The control method designed to eliminate main harmonics in a microgrid (MG) and between MG and point of common coupling (PCC) and responsible for the correction of the system unbalance. Another advantage of the proposed control method is that it can be easily adopted into the DG control system without the installation of extra hardware. The proposed control method is comprised of the synchronous reference frame method (SRF). Results from the proposed control method are provided to show the feasibility of the proposed approach.</dc:description>
	<dc:publisher xml:lang="en-US">Institute of Advanced Engineering and Science</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2017-03-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US"></dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6155</dc:identifier>
	<dc:identifier>10.11591/ijpeds.v8.i1.pp272-278</dc:identifier>
	<dc:source xml:lang="en-US">International Journal of Power Electronics and Drive Systems (IJPEDS); Vol 8, No 1: March 2017; 272-278</dc:source>
	<dc:source>2722-256X</dc:source>
	<dc:source>2088-8694</dc:source>
	<dc:source>10.11591/ijpeds.v8.i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ijpeds.iaescore.com/index.php/IJPEDS/article/view/6155/7555</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2017 A. Naderipour, A. A. Mohd Zin, M. H. Habibuddin, M. Moradi, M. Miveh, H. N. Afrouzi</dc:rights>
	<dc:rights xml:lang="en-US">http://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>